2OM-1064-002.pdf - 第230页
0004-001 6-6 Tg0247-PM-PM

Second Page
P.E.C. TIMER
Set the waiting time (time to wait for the machine to start the
recognition operation after the P.E.C. camera has moved to
the P.C.B. recognition position) in the increments of seconds
(ms).
• Data Input Range
0 to 9999 ms
• Standard Value
150 ms
COMP. RECOG. TIMER
Set the waiting time (time to wait for the machine to start the
recognition operation after the component recognition camera
has completed its movement) in the increments of seconds (ms).
• Data Input Range
0 to 9999 ms
• Standard Value
50 ms
PLACEMENT TIMER
Set the waiting time (time to wait for the machine to start the
placement operation after the machine has moved to the com-
ponent placement position) in the increments of seconds (ms).
• Data Input Range
0 to 9999 ms
• Standard Value
0 ms
1. TEST MODE Display
9910-001 6-5 Tg0247-PM-PM

0004-001 6-6 Tg0247-PM-PM

Section 7
Nozzle Stocker Data
9910-001 7-1 Tg0247-PM-PM