2OM-1064-002.pdf - 第229页
Second Page P .E.C. TIMER Set the waiting time (time to wait for the machine to start the recognition operation after the P .E.C. camera has moved to the P .C.B. recognition position) in the increments of seconds (ms). •…

1. TEST MODE Display
9910-001 6-4 Tg0247-PM-PM
COMPONENT RECOGNITION
The processing with the component recognition camera can
be canceled.
When “DISABLE” is set in the data box, the processing with
the component recognition camera is not implemented.
Note : In the case of the component recognition, the devia-
tion in component position is regarded as “0” (zero).
P.E.C. GAIN/LEVEL DISPLAY
Set “ENABLE” or “DISABLE” in the data box.
When “ENABLE” is set, the gain & level data used for P.E.C.
recognition is displayed on the recognition monitor.
HANDLING/PLACEMENT MODE
Set “ENABLE” or “DISABLE” in the data box.
When “DISABLE” is set in the data box, the machine does
not perform any pick-up and placement operation.
COMPONENT FEED
Set “ENABLE” or “DISABLE” in the data box.
When “DISABLE” is set in the data box, the machine does
not perform any feeder forward movement and component
feeding from the tray feeder.
VACUUM/BLOWER OFF MODE
The vacuum pump motor can be forcibly stopped.
When “DISABLE” is set in the data box, the vacuum pump is
deactivated.
NOZZLE CHANGE STOP
Set “ENABLE” or “DISABLE” in the data box.
When “DISABLE” is set in the data box, the nozzle change
error detection function is canceled.
TRAY MATRIX UPDATE: Option
The update of the tray matrix can be canceled.
When components are picked up from the tray, the matrix po-
sition of the tray moves in normal cases. However, when “DIS-
ABLE” is set, components are always picked up from the fixed
matrix position (the matrix position of the same tray).
SHORTAGE OF CMPNT (TRAY): Option
The tray component shortage detection can be canceled.
When “DISABLE” is set in the data box, the machine does
not perform the tray component shortage detection and con-
tinues the pick-up operation.
(After the machine has picked up all component, it starts to
pick up components from the first cell of the tray.)

Second Page
P.E.C. TIMER
Set the waiting time (time to wait for the machine to start the
recognition operation after the P.E.C. camera has moved to
the P.C.B. recognition position) in the increments of seconds
(ms).
• Data Input Range
0 to 9999 ms
• Standard Value
150 ms
COMP. RECOG. TIMER
Set the waiting time (time to wait for the machine to start the
recognition operation after the component recognition camera
has completed its movement) in the increments of seconds (ms).
• Data Input Range
0 to 9999 ms
• Standard Value
50 ms
PLACEMENT TIMER
Set the waiting time (time to wait for the machine to start the
placement operation after the machine has moved to the com-
ponent placement position) in the increments of seconds (ms).
• Data Input Range
0 to 9999 ms
• Standard Value
0 ms
1. TEST MODE Display
9910-001 6-5 Tg0247-PM-PM

0004-001 6-6 Tg0247-PM-PM