2OM-1064-002.pdf - 第21页
*2 *1 *3 2.1.4 PLACEMENT DA T A SORTING Display • When the created placement data (U-No.) is used without any modification, the machine cannot perform its component placement operation efficiently , concluding that longe…

*6 NOZ. STKR.
The conditions of the nozzles actually set in the nozzle stockers can be
checked.
Colour code (coloured nozzle IDs) are used to indicate the nozzles use con-
ditions as shown in the following table.
Table 2.1
2. Pattern Program
Character Color
Background
Color
Condition
Green Black Used in Selected Pattern Program
White Black Not Used in Selected Pattern Program
None Red Bypassed Nozzle Stocker Address
No Indication None Nozzle Stocker Empty
0004-002 2-8 Tg0247-PM-PM

*2
*1
*3
2.1.4 PLACEMENT DATA SORTING Display
• When the created placement data (U-No.) is used without any modification,
the machine cannot perform its component placement operation efficiently,
concluding that longer time may be required to finish one P.C.B.
Such placement data can be re-arranged in the most effective order at this
display.
Requirements for Placement Data Sorting
Number of Nozzle Change Operations
• This placement data sorting function shortens the time for the machine to
read the data, improving the productivity.
When the “NAME (XX/XX)” key of the program data to be sorted is selected
and the [PLACEMENT DATA SORTING] key is pressed at the “PATTERN
PROGRAM” display (Fig. 2.1), the following display appears on the screen.
2. Pattern Program
Fig. 2.4-1
*1 [ON] Key
Select this key when the automatic pairing function should be used. The
“S-DATA” of the placement data is initialized and the pairing operations
are performed for the simultaneous pick-up and pick-up priority functions,
and then the program is optimized.
*2 [OFF] Key
Select this key when the automatic pairing function should not be used.
The program is optimized, keeping the current “S-DATA” of the placement
data intact (not initialized).
*3 [CANCEL] Key
Select this key to interrupt the placement data sorting.
9910-001 2-9 Tg0247-PM-PM

When the [ON] or the [OFF] key is pressed at the “PLACEMENT DATA SORT-
ING” display (Fig. 2.4-1), the following display appears on the screen and the
program check operation is performed.
2. Pattern Program
9910-001 2-10 Tg0247-PM-PM
Fig. 2.4-2
The program is checked “OK”, the placement data sorting is implemented.
When the sorting is completed normally, the program is checked again.
When the second program check operation is completed normally, the “PAT-
TERN PROGRAM EDIT” display appears on the screen.
• When the program is checked “NG” (No Good), the contents of the error are
displayed as shown in Fig. 2.4-3.
When an error is found during sorting, the contents of the error are also
displayed.
Correct the error data and perform the sorting again.
Fig. 2.4-3