2. NOZZLE TYPE DA T A Display NOZZLE LENGTH Set the nozzle length in the data box. <Options> “19.0 mm” (Short Nozzle) “32.0 mm” (Long Nozzle) : (Unavailable at Present) There are two types of vacuum nozzles - short…

Fig. 8.2-1
Fig. 8.2-2
[PREV PAGE] [NEXT PAGE]
Second Page
First Page
First Page
2. NOZZLE TYPE DATA Display
Parameters can be set for various nozzles at this display.
Each data must be registered in the machine.
When the ID of the nozzle to be edited is selected at the “NOZZLE LIBRARY
INFO” display and the [DATA EDIT] key is pressed, the following display
appears on the screen.
Every time the [NEXT PAGE] or the [PREV. PAGE] key is pressed, another or
previous page appears on the screen.
2. NOZZLE TYPE DATA Display
0004-002 8-3 Tg0247-PM-PM
SHAPE
Set the shape of the nozzle tip in the data box.
“ROUND” or “RECTANGLE”
Note: In the case of a rectangular nozzle, the pre-rotational
pick-up control (control based on the parameter set in
the “PICK-UP ANGLE” data box at the “COMPONENT
LIBRARY EDIT” display) may be required depending
on the packaged posture of a component.
Refer to “2.2 Component Library Data Items in COM-
PONENT LIBRARY” for details.

2. NOZZLE TYPE DATA Display
NOZZLE LENGTH
Set the nozzle length in the data box.
<Options>
“19.0 mm” (Short Nozzle)
“32.0 mm” (Long Nozzle) : (Unavailable at Present)
There are two types of vacuum nozzles - short and long ones.
The length between the lower surface of the diffusion plate
and the nozzle tip must be entered.
19.0 mm
32.0 mm
Standard Type (Short Nozzle) Long Type (Long Nozzle)
Diffusion Plates
Note
(
b
)
Fig. 8.3
Notes: (a) A short nozzle can be used for components of half an inch or less
(component thickness T: 12.70 mm or less).
Long nozzles must be used only when a hindrance is caused dur-
ing pick-up or placement operation due to the regulatory condi-
tion of the component shape and height and the height of the pre-
viously-placed components.
(b) Consult our service personnel separately for long nozzles.
(Unavailable at Present)
9910-001 8-4 Tg0247-PM-PM

Fig. 8.4 Sectional View A-A’
TIP POLARITY EXISTENCE
Set “ENABLE” or “DISABLE” in the data box to specify
whether or not the polarity exists in the shape of the nozzle
tip.
ENABLE : Special Nozzle with Polarity (asymmetrical)
DISABLE : Round Nozzle or the like without Polarity
FIDUCIAL MARK IMAGE
Specify how (bright or dark) the image of the nozzle tip is
captured in the front lighting system.
The set parameter is required for nozzle masking in the front
lighting recognition.
“BRIGHT” or “DARK”
In normal cases, set “BRIGHT” in the data box.
LIGHTING METHOD
Determine in which lighting system (“BACK”, “FRONT”, or
“FRONT+BACK”) the nozzle can be used.
“BACK”
“FRONT”
“FRONT+BACK”
Ref.: “FRONT” must be selected for such a nozzle that the
image of the area other than the nozzle tip appears dark
in the back lighting system.
“BACK” must be selected for such a nozzle that the
image of the area other than the nozzle tip appears
bright in the front lighting system.
“FRONT+BACK” must be selected when “ROUND”
is set in the “SHAPE” data box.
V-GROOVE SIZE: Reserved Data
When the V-grooved nozzle is used for cylindrical compo-
nents, set the size of the V groove in the data box.
• Data Input Range
0 to 99.99 mm
In the case of the nozzle without a V groove, set “0” (zero) in
the data box.
NOZZLE OUTER SIZE X (Horizontal) and Y (Vertical)
Set the outer dimensions of the nozzle tip section.
In the case of “ROUND”, set the same dimensions for “X”
and “Y”.
In the case of “RECTANGLE”, set the dimension of the longer
side in the “X” data box and the dimension of the shorter one
in the “Y” data box.
• Data Input Range
X: 0 to 99.99
Y: 0 to 99.99
2. NOZZLE TYPE DATA Display
X
Y
Y
X
Imprinted Nozzle ID
Diffusion Plate
Imprinted Nozzle ID
Diffusion Plate
A
’
A
0004-002 8-5 Tg0247-PM-PM