YSM20R_YSM20WR_Ope_E.pdf - 第106页
2-3 2 Basic operation 1.3 T ypical errors and troubleshooting T ypical errors that might be displa yed during oper ation are shown below along with possible causes and correctiv e action. n Head or nozzle-related errors …

2-2
2
Basic operation
1.2 Clearing an error
If an error occurs a buzzer sounds and a warning screen appears. To clear the error, use the following steps.
1
Turn off the buzzer.
Press the [ERROR CLEAR] button on the operation panel or the [BUZZER OFF] button on the error screen
to turn off the buzzer.
2
Check the cause of the error.
Possible causes are displayed on the lower part in the error screen, so check or make a note of the
description.
3
Clear the error screen.
Press the [ERROR CLEAR] button again or the [ERROR CLEAR] button on the error screen to clear the
error screen.
4
Check the signal light and screen display.
Check that the yellow lamp of the signal light is off and the error message on the left of the status area
on the operation screen is now off.
[BUZZER OFF] button [ERROR CLEAR] button
Error screen
Mark detection error
24225-KMK-00

2-3
2
Basic operation
1.3 Typical errors and troubleshooting
Typical errors that might be displayed during operation are shown below along with possible causes and
corrective action.
n
Head or nozzle-related errors
Code Error name and description
Ea00097
NOZZLE RECOGNITION ERROR
State
Intensity of Component pole is not enough at threshold level. Nozzle is recognized as a component. Please
check nozzle and clean it.
Cause
Component electrode brightness did not reach the brightness ("Comp. Intensity" parameter setting) that can
be identified as a component. A nozzle might have been misrecognized as a component.
Action Check the nozzle that caused the error and clean it. Adjust the "Comp. Intensity" parameter in parts data.
Ea00204
NOZZLE STATION ERROR
State There is no nozzle present for the next sequence. Please check nozzle station data.
Cause Nozzles to be used are not specified in nozzle station information.
Action Check the settings in nozzle station information.
Ea00864
INTERLOCK ERROR
State
You can't move X ,Y ,R or W axis, because Z axis is moving or Z axis position safety sensor is OFF. Please
check Z axis position.
Cause Head is lowered or sensor is defective.
Action Raise the head (Z-axis) by hand.
Ea00865
INTERLOCK ERROR
State You can't move X or Y axis, because there isn't a nozzle station at the bottom.
Cause Nozzle station is raised, or the lower end sensor in the nozzle station does not work.
Action
Lower the nozzle station in manual mode. With the nozzle station lowered, check I/O monitor to see if the
sensor is working. If not, replace the sensor.
Ea00880
<<WARNING VACUUM LEVEL ERROR>
MOUNT IO SEQUENCE VACUUM LEVEL ERROR
State
Vacuum level has not reached the specified level. Please check the nozzle and valve condition. This may
cause bring-back cmp. or double mount problem.
Cause
Negative pressure was insufficient during component placement. A nozzle might have brought a component
back without placing it on the board.
Action Open the [Unit] – [Head] tab and immediately check the nozzles and valves.
Ea02652
INTERLOCK ERROR
State You can't move X ,Y ,R or W axis, because Z axis is not in safe position. Please check Z axis position.
Cause The head position is at a dangerous height, so the X, Y, R and W axes cannot move.
Action Raise the head to a safe height. If the machine's head has a lower end sensor, then check the sensor status.
Ea02653
INTERLOCK ERROR
State Z axis is not in a safe position. Please check Z axis position.
Cause The head position is at a dangerous height right after return-to-origin is performed.
Action Check that the current head position (Z-axis) is lowered to a dangerous height.
Ea02778
BNC NOZZLE PICKUP ERROR
State
Failed to pick up a nozzle from the nozzle station.
Since the vacuum level of the head is below the Shaft Release Level, the machine cannot be confirmed to
pick up a nozzle.
Cause
1. The head was not able to store a nozzle.
2. Although the head has stored a nozzle, the vacuum level is larger than the Shaft Release Level.
Action
1. Please adjust the height, angle and position data of the nozzle station.
2. Please adjust the [VmSpec] - [Machine Data] - [Head] - [Vacuum Level] - [Shaft Release Level].

2-4
2
Basic operation
Code Error name and description
Ea02779
BNC NOZZLE STORE ERROR
State
Failed to store a nozzle from the nozzle station.
Since the vacuum level of the head is larger than the Shaft Release Level, the machine cannot be confirmed
to store a nozzle.
Cause
1. The head was not able to store a nozzle.
2. Although the head has stored a nozzle, the vacuum level is larger than the Shaft Release Level.
Action
1. Please adjust the height, angle and position data of the nozzle station.
2. Please adjust the [VmSpec] - [Machine Data] - [Head] - [Vacuum Level] - [Shaft Release Level].
Ea02906
NOZZLE CHANGE STATUS ERROR
State
The specified nozzle on this head is impossible. Please make sure the following item:
- Status of Nozzle Station.
Cause Cannot identify the currently attached ANC nozzle.
Action Check the nozzle station sensor status.
Ea07563
Shaft Cleaning Blow Nozzle Misplaced Error.
State Could have been out of nozzle from head, when execute shaft clean blow.
Cause No nozzle can be detected at the head.
Action
Each head at the above table, check the following contents.
- That it is not left behind the nozzle to blow unit.
- Come away the nozzle from the head, fell in the machine or not.
- Do not under-take the nozzle from the head.
Ea29528
INTERLOCK ERROR
State Failed to move the scan axis (SC-axis).
Cause
The scan axis (SC-axis) cannot be moved since the head lowers to a height where it interferes with the scan
camera.
Action Execute the reset and restart the work.