YSM20R_YSM20WR_Ope_E.pdf - 第51页
1-18 1 Unit names and functions 4 A confirmation screen appears asking you to make a final check. Check the contents of the screen and press the correspondi ng button. [YES] : Per forms nozzle shaft blow of the selected …

1-17
1
Unit names and functions
3.4.2 Manual nozzle shaft blow procedure
This section explains how to manually perform a nozzle shaft blow at any desired timing.
1
Open the [Unit] – [Head] screen.
2
Press the [Cleaning Blow] button.
Nozzle shaft blow
[Cleaning Blow] button
24100-KMK-00
3
Specify the nozzles you want to clean by nozzle shaft blow.
The "Nozzle Setting" screen will appear. Select the table where the nozzle shaft cleaning blow is per-
formed, put a check mark on the nozzles, and then press the [OK] button.
Nozzle Setting screen
Select the check boxes for the nozzles you want to clean by nozzle shaft blow.
Select the table.
24101-KMK-00
c
CAUTION
When the nozzle is not subject to the nozzle shaft blow, the nozzle may collide with the air-blow station, causing
breakage. Before starting the nozzle shaft blow, be sure to check that the set nozzles meet the installed nozzles.

1-18
1
Unit names and functions
4
A confirmation screen appears asking you to make a final check.
Check the contents of the screen and press the corresponding button.
[YES] : Performs nozzle shaft blow of the selected nozzles.
[NO] : Returns to the "Nozzle Setting" screen.
[CANCEL] :
Closes the dialog box and returns to the [Unit]-[Head] screen without performing nozzle shaft blow.
“RECONFIRMATION OF CLEANING BLOW” screen
24102-KMK-00
n
When the machine has a nozzle station (option)
When the settings are made so that all nozzles can be changed using a nozzle station (option), follow these steps.
1
Open the [Unit] – [Head] screen.
2
Press the [Cleaning Blow] button.
[Cleaning Blow] button
Nozzle shaft blow
When nozzle station (option) is used
24103-KMK-00

1-19
1
Unit names and functions
3
Specify the nozzles you want to clean by nozzle shaft blow.
The "Nozzle Setting" screen will appear. Select the target nozzle and table for the nozzle shaft cleaning
blow. Put a check mark on the nozzles, and then press the [OK] button.
Nozzle Setting screen
Select the check boxes for the nozzles you want to clean by nozzle shaft blow.
Select the table.
Select the target nozzle.
24104-KMK-00
c
CAUTION
When the nozzle is not subject to the nozzle shaft blow, the nozzle may collide with the air-blow station, causing
breakage. Before starting the nozzle shaft blow, be sure to check that the set nozzles meet the installed nozzles.