YSM20R_YSM20WR_Ope_E.pdf - 第113页

2-10 2 Basic operation n Buttons and parameter input boxes V arious types of buttons, selection tabs and parameter input boxes are used on the operation screen. 1 1 2 3 4 5 6 7 Operation screen basic elements Mark screen…

100%1 / 229
2-9
2
Basic operation
n
"Mount compilation rate" on status area
The "Mount compilation rate" is displayed on the status area if the software version is 4.65 R1.000 or later.
The mount status on board per stage/lane can be checked.
Note that [>>] / [<<] button on the status area hides/reveals the mount compilation rate.
Status area
Display of "Mount compilation rate"
Stage 1
Reveal/Hide
button
Stage 2
Lane 1
Lane 2
Dual-stage type
Dual-lane type
24236-KMK-00
TIP
The mount compilation rate is calculated with the following formula.
Mount compilation rate (%) = (The number mount is completed / The number of all mounts) × 100
Note that the mount point where the mounting is not performed due to the bad mark for instance is not included in
the mount completion rate. Therefore, the final mount compilation rate may not be 100%.
Additionally, the skipped mount point is not included in the calculation. If no mount data exists, "-" is displayed.
The mount compilation rate returns to 0% by reloading a board data.
2-10
2
Basic operation
n
Buttons and parameter input boxes
Various types of buttons, selection tabs and parameter input boxes are used on the operation screen.
1
1
2
3
4
5
6
7
Operation screen basic elements
Mark screen
Parameter listData No. list
24201-KMK-00
1. Scroll bar and button (up/down, left/right)
Use the scroll bars or arrow buttons to see hidden items in the data No. list or parameter list.
2. Operation button
Press these buttons to open the next operation screen or dialog box.
3. Line up/down button
Use these buttons to move the cursor up or down through the data No. list or parameter list.
4. Parameter input box
Select, enter or edit parameters here. When the keyboard is used, double-click on a parameter input box to enter or edit
the data.
To operate the touch panel for data entry, press the corresponding “Edit” buttons on the right side of the screen to have
the edit box pop up.
5. Selection tab
Select this tab to switch the parameter input screen.
6. Assistant screen
Shows an illustration or information useful for parameter input or editing.
Alphabet characters shown in the parameter list and in the illustration on this screen correspond to each other.
7. Capture button
Captures the displayed image. The captured data (JPEG format) is stored in the D:\ScreenShot folder (maximum folder
size: approx. 10MB), with a file name consisting of the date and time.
When a USB memory device is inserted into the machine’s USB port and system backup is performed, a “ScreenShot”
folder is created in the root of the USB memory device to acquire the captured data stored in the machine. (The captured
data stored in the machine is moved to the USB memory device.)
c
CAUTION
When saving data in a USB flash memory, make sure to use the USB flash memory designated by YAMAHA.
If you specify the destination to save the data on the “Screen Shot Setting” window (Press the [Setup] – [Software
Setting] – [Information] – [Screen Shot Setting] buttons), the captured data cannot be saved in the USB flash memory
even by performing System backup.
2-11
2
Basic operation
About error screen
1
2
3
6 7
4 5
Error screen
Mark detection error
[Error Switching] button
24202-KMK-00
1. Error count display
Shows the currently displayed error and the total number of errors. If two or more errors occurred, use the [Error
Switching] buttons (right/left arrow buttons) to switch to other error screens.
2. Message switching tab
Outline:
Displays a message for the operator.
Detail:
Displays a message for the administrator/supervisor or service personnel. This tab does not appear unless a message is
available.
3. Recognition image display (component pickup error and mark recognition error screens)
If an error has occurred in image processing during component pickup or mark recognition, the error image is displayed
here.
4. [BUZZER OFF]
Turns off the buzzer.
5. [ERROR CLEAR]
Clears the error that has occurred.
6. [Language] button
Switches the language of the message displayed on the error screen.
7. [Close] button
Closes the error screen without clearing the error.
TIP
The positions where errors occurred can be checked graphically by opening the [Monitor] - [Production] tab after
closing the error screen by pressing the [Close] button. Pressing the [Error Detail] button on the [Production] screen
redisplays the error message. See "3.1 Production" in this chapter for the [Production] screen.