EUKYX-199-3100_G5S2_Instruction_Vol3_E.pdf - 第100页
EUKYX 1-51 199-3100 5.14 Noz Incln • T eaching Jig The QFP gl ass jig J G- 01 88 ( K YB -M38 1 P- 00 ) is used when teac hi ng the head /nozzl e in cl ina tion of fset and NS p ositi on. • Jig Pick -up Nozz le For the pi…

EUKYX
1-50199-3100
5.14 Noz Incln
5.14 Noz Incln
This window is not displayed when the multi-functional head is selected.
The teaching for the offset data to correct the head nozzle inclination or NS position is performed.
[1] [2]
Graphic
Development
F3A45A
[1] Teaching Data Display Section
Displayed are the teaching data items for the nozzle in the designated head.
[2] Teaching procedures section
The following buttons are arranged in teaching procedures section.
Select Head
Select the head for the nozzle to be taught.
The window can be changed over using the tabs on the window.
Select Tch
Select "NozInclin" or "Ns Pos" to be taught.
[Noz All] button
Teaches all the nozzles.
[Noz] button
Designate the nozzle to be taught in this area.
When the [Noz] button is selected and [Noz No] is pressed, the input window appears.
[Teach Start] button
Starts the teaching.
[Save] button
The teaching results are saved.
Note
Note

EUKYX
1-51199-3100
5.14 Noz Incln
• Teaching Jig
The QFP glass jig JG-0188 (KYB-M381P-00) is used when teaching the head/nozzle inclination
offset and NS position.
• Jig Pick-up Nozzle
For the pick-up of the QFP glass jig, the jig nozzle (standard equipment) or the normal vacuum
nozzle HV19C is used.
• Teaching Procedure
(1) Before the teaching operation, change the nozzle to the jig nozzle and setup the QFP glass
jig in the jig setup position over the component recognition camera.
(2) Select the head (1 or 2) and nozzle to be taught.
(3) Select “NozIncln“ or “NS Pos“ for “Select Tch“.
(4) Select the head (1 or 2) and nozzle to be taught.
During this temporary stop mode, the selection of any other menu item is unavailable. When
the offset teaching is completed, the designated head returns to the home position
automatically. The teaching results are displayed in the "Head/Noz Incln Offset" Display Area.
(5) Repeat the steps (1) through (4) to teach the nozzles for which the inclination teaching
operation is required.
(6) When the teaching operation is completed, remove the QFP glass jig.
(7) Press the [Save] button. (When this button is pressed, the teaching results are saved.)
Procedure
Note

EUKYX
1-52199-3100
5.15 Noz Lv./Pos.
5.15 Noz Lv./Pos.
This window is not displayed when the multi-functional head is selected.
Noz.Lv.
This window enables you to perform teaching operations on the nozzle level (lower surface) offsets
of the ordinary nozzles on the heads.
Noz.Pos.
This window performs teaching operations on the deviations from the reference values between the
head rotational centers and the nozzle end positions.
[3]
[1]
[2]
Graphic
Development
F3A46
[1] Head Change Tabs
When each tab is pressed, the corresponding tab sheet for the head for each teaching operation,
appears.
[2] Teaching Data Display Section
Displayed are the teaching data items for the nozzle in the designated head.
[3] Teaching procedures section
The following buttons are arranged in teaching procedures section.
Select head
Select the head for the nozzle to be taught.
Select [All] when the teaching is performed for all the nozzles, .
When the head is selected with "Select Head" the window is changed accordingly.
Note
Note