EUKYX-199-3100_G5S2_Instruction_Vol3_E.pdf - 第192页

EUKYX 2-44 199-3100 2.7 Nozzle Stocker 2. 7 Nozzle St ocker Pressi ng the [Nozzl e Stock er] but ton on the "O f fset Data" w indow d ispla ys the fol low in g wi ndow . [4] [2] [1] [3] Graphic Development F3B5…

100%1 / 230
EUKYX
2-43199-3100
2.6 Nozzle
2.6.8 Noz Sel Axis Pos
Pressing the [Noz Sel Axis Pos] tab on the "Nozzle" window displays the following window.
[2][1]
Graphic
Development
F3B55A
[1] Nozzle
Each Nozzle No. is displayed in these boxes.
[2] Head1 / Head2
Z [Ang]
These offset parameters are used to correct the position relation between the nozzle selection axis
and the nozzle.
EUKYX
2-44199-3100
2.7 Nozzle Stocker
2.7 Nozzle Stocker
Pressing the [Nozzle Stocker] button on the "Offset Data" window displays the following window.
[4]
[2]
[1]
[3]
Graphic
Development
F3B56
[1] Offset button
When this button is pressed, the offset data for the selected tab is displayed.
When the [Stocker Master] tab is pressed, the set values of 1-1 through 1-4 and 2-1 through
2-4 are displayed.
[2] Offset Data Display Section
In this section, the offset data selected in step [1] is displayed.
[3] [Return] button
When this button is pressed, the window returns to the “Offset Data” window.
[4] [Save] button
When this button is pressed, the input data is saved.
[Cancel] button
When this button is pressed the input data is cancelled and the window returns to the saved data.
Note
EUKYX
2-45199-3100
2.7 Nozzle Stocker
2.7.1 1-1 to 1-4, 2-1 to 2-4
Pressing the [1-1] tab on the "Nozzle Stocker" window displays the following window.
(a) The same tab sheet appears from [1-2] to [2-4].
(b) The tab sheet may look different, depending on which options are selected.
[1]
[2]
Graphic
Development
F3B57
[1] X (Horizontal) / Y (Vertical) [mm]
This offset data is used to adjust the nozzle change position deviation from the nozzle stocker unit
position designed value based on the PCB locating base XY coordinates (Machine Reference XY
Coordinates: Origin P0).
The Machine Reference XL Coordinates are set to the reference values.
When positive (+) value is set for the offset value, the nozzle change position is changed to
directions X(+) and Y(+).
[2] L (Height) [mm]
When a value is entered with a plus (+) sign, the nozzle change position (height) is changed in the L
(+) direction, concluding that the descending stroke has increased.
Nozzle
Nozzle Mounting Level
(Upper Surface of Nozzle Stocker Block)
L(+)
F3B58
The above "L" is effective only in the master nozzle.
Note
Note