EUKYX-199-3100_G5S2_Instruction_Vol3_E.pdf - 第134页
EUKYX 1-85 199-3100 6.3 RECOG 6.3.4 Count Board Pressi ng the [Count Board] t ab on the [ RECOG] window d isp la ys the fol low in g wi ndow . [1] [2] [3] Graphic Development F3A79 [ 1 ] Bea mBack X, Y / B eamFront X, Y …

EUKYX
1-84199-3100
6.3 RECOG
6.3.3.2 PEC Recog
Pressing the [PEC Recog] sub tab on the [Capture Img.] tab displays the following window.
[1]
[2]
Graphic
Development
F3A78
[1] Select camera
In this section, the PEC recognition camera for capturing the component image is selected.
[2] [Capture Img.] Button
Using this button, the image is captured using the selected camera.

EUKYX
1-85199-3100
6.3 RECOG
6.3.4 Count Board
Pressing the [Count Board] tab on the [RECOG] window displays the following window.
[1]
[2]
[3]
Graphic
Development
F3A79
[1] BeamBack X, Y / BeamFront X, Y
In these data boxes the X, Y count values are displayed for each beam.
[2] XY Beam Image
Displayed are the X and Y beam images.
[3] [Count Confirm] Button
When this button is pressed, the current counter value is checked.
The change position and increase/decrease direction of the count value displayed by means of
pressing the beam manually and pressing the [Count Confirm] button, are confirmed.

EUKYX
1-86199-3100
6.3 RECOG
6.3.5 Others
Pressing the [Others] tab on the [RECOG] window displays the following window.
[1]
[2]
Graphic
Development
F3A80
[1] 2D license
In this data box the valid or invalid of the optional 2-D bar code read license (GS-DL100) is
displayed.
[2] [Confirm] Button
Using this button the valid or invalid of the optional 2-D bar code read license (GS-DL100) is
confirmed.