EUKYX-199-3100_G5S2_Instruction_Vol3_E.pdf - 第187页
EUKYX 2-39 199-3100 2.6 Nozzle 2.6. 2 Nozzle Position Pressi ng the [Nozzl e Pos ition] tab on the "Nozzl e " wi ndow di spla ys the fol lowi ng window . [1] [2] Graphic Development F3B48A [1] N o z z l e In th…

EUKYX
2-38199-3100
2.6 Nozzle
2.6.1 Nozzle Level A
Pressing the [Nozzle Level A] tab on the "Nozzle" window displays the following window.
[1] [2]
Graphic
Development
F3B47A
[1] Nozzle
In this section, each nozzle No. is displayed.
[2] Head 1 and Head 2
L (Height) [mm]
Each parameter indicates the offset of the bottom level of the normal nozzles on each individual
heads. Measure each nozzle bottom level with a side view camera while the nozzle U/D axis is
zeroed and save the difference between the level and the master nozzle level offset.
These parameters are calculated using the formula "Nozzle Level Offset = Master Nozzle
Level - Measured Value of Normal Nozzle Level".
Note

EUKYX
2-39199-3100
2.6 Nozzle
2.6.2 Nozzle Position
Pressing the [Nozzle Position] tab on the "Nozzle" window displays the following window.
[1] [2]
Graphic
Development
F3B48A
[1] Nozzle
In this section, each nozzle No. is displayed.
[2] Head 1 and Head 2
X (Horizontal) and Y (Vertical) [mm]
Displayed is the offset data for the lowest levels of the normal nozzles on the heads. The lowest
level of each nozzle is measured by the component recognition camera and the difference between
the actual and recognized levels is compensated for.
Xm(+)
Ym(+)
Xm-Ym :
DD (+)
DD (+)
Nozzle Designed Position
Real Nozzle Position
Pm. Machine Reference
Coordinate Origin
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Machine Reference
Coordinate System
F3B49

EUKYX
2-40199-3100
2.6 Nozzle
2.6.3 Master Noz Lv (Indv.)
Pressing the [Master Noz Lv (Indv.)] tab on the "Nozzle" window displays the following window.
[1] [2]
Graphic
Development
F3B50A
[1] Nozzle
In this section, each nozzle No. is displayed.
[2] Head 1 / Head 2
L [mm]
Each parameter indicates the reference position (the values read by the side view camera) of the
master nozzle bottom level.
Save the values of the master nozzle bottom level that was read by the side view camera and used
when the head up/down offsets were obtained with the nozzle U/D axes being zeroed.
2.6.4 Master Nozzle Level
Pressing the [Master Nozzle Level ] tab on the “Nozzle” window displays the following window.
[1]
Graphic
Development
F3B51A
[1] Head 1 / Head 2
L [mm]
Each parameter indicates the reference position (the values read by the side view camera) of the
master nozzle bottom level.
Save the values of the master nozzle bottom level that was read by the side view camera and used
when the head up/down offsets were obtained with the nozzle U/D axes being zeroed.