5.10 Head Rotate Axis
Teaching Vacuum Nozzle
For the head rotation axis offset teaching, the two jig nozzles (standard equipment) and one normal
vacuum nozzles HV19C. Before the teaching operation, change the nozzles on the "NOZ.CHNG."
window (Operation Sequence: Select [Unit Adj.] button in the Menus for Maintenance
Select
[Noz Chng.] button). At that time, attach the nozzles onto the nozzle No. 1 positions.
Teaching Procedure
(1) Select the head (1, 2 or All) for which the head rotation axis offset teaching is performed.
In the case that the multi-functional head is selected, select the nozzle to be taught and press
the [Teach Start] button.
(2) Press the [Teach Start] button. (The designated beam will be moved to the specified
position and the head rotation axis offset is taught.)
During this temporary stop mode, the selection of any other menu item is unavailable.
When the offset teaching is completed, the designated head returns to the home position
automatically. The teaching results are displayed in the “Beam XY Offset Confirmation” Display
Area.
(3) Press the [Save] button. (The teaching results are saved.)
Procedure
Note
Note
EUKYX
1-44199-3100
5.11 Head Cntr Mark Pos
5.11 Head Cntr Mark Pos
In this window, the teaching for the offset data is performed to correct the deviation of the head
rotation center from the PEC recognition camera center reference value. Also, the reference mark
position is taught, which was caught using the PEC recognition camera when the head rotation
center is moved onto the component recognition camera view.
“Head Cntr” tab
“Mark Pos” tab
“Light Emitter Mark” tab
[1]
[1]
[1]
[2]
[2]
[2]
[3]
Graphic
Development
F3A39
EUKYX
1-45199-3100
5.11 Head Cntr Mark Pos
[1] Teaching Data Display Section
Displayed are the each offset data items for the designated camera and head.
[2] Teaching procedures section
The following buttons are arranged in teaching procedures section.
Select camera
Selects the camera to be taught.
Select head
Selects the head to be taught.
Change Window Display
Pressing each button corresponding to each teaching operation, changes over the window to
the corresponding teaching window.
When the window is changed over, the teaching in the displayed window is performed.
The buttons corresponding to each window are as follows.
Head Cntr : The window is changed to the teaching window for the head rotation
center.
Mark Pos : The window is changed to the teaching window for the reference mark
position.
The window can be changed over using the tabs in the window.
[Noz All] button
Teaches all the nozzles.
[Noz] button
The nozzle for which the teaching is preformed is designated.
When the [Noz] button is pressed, the input window appears.
[Teach Start] button
Starts the teaching.
[Save] button
The teaching results are saved.