EUKYX-199-3100_G5S2_Instruction_Vol3_E.pdf - 第208页

EUKYX 2-60 199-3100 3.1 Auto Ope. Set-up [ 5] Noz repl ace in the lowering of p icks Select "Enable" or "Di s abl e" to ch ange the no z zl e autom ati cal ly to a spare no zzle i n t he stock er when…

100%1 / 230
EUKYX
2-59199-3100
3.1 Auto Ope. Set-up
[3] Fdr msg rate
Err counts [times], pick [times]
Set the parameters to show the feeder slot No. (Fdr. No.) of the tape feeder whose pickup rate has
deteriorated during automatic operation. When the number of picks has reached the specified
value, the parameter in the "Error counts" text box is cleared.
The number of picks and pick-up errors is managed for each individual feeders but the
parameters of "Error counts" and "# of picks" is equally reflected on every feeder.
Guide
"WARNING", "Stop (Cycle stop), or "Pause" can be selected to determine in which mode the
machine should be set when the number of pickup errors has reached the specified error counts
before the number of picks reaches the specified number of picks. When "Warning" is selected, a
warning message is issued as machine information. "Stop (Cycle stop)" stops the machine after one
cycle of operation and "Pause" sets the machine in the "PAUSE" mode.
When both "Error counts" and "# of picks" are set "0" (zero) or "Error counts" is set to a
number larger than "# of picks", no warning message is issued.
[4] Fdr(Noz) msg rate
Err counts [times], pick [times]
Error counts and # of picks [times] Set the parameters to show the nozzle No. whose pickup rate
has deteriorated during automatic operation.
When the number of picks has reached the specified value, the parameter in the “Error counts” text
box is cleared.
The number of picks and pick-up errors is managed for each individual nozzles but the
parameters of “Error counts” and “# of picks” is equally reflected on every nozzle.
Guide
“WARNING”, “Stop (Cycle stop), or “Pause” can be selected to determine in which mode the
machine should be set when the number of pickup errors has reached the specified error counts
before the number of picks reaches the specified number of picks. When “WARNING” is selected,
a warning message is issued as machine information. “Stop (Cycle stop)” stops the machine after
one cycle of operation and “Pause” sets the machine in the “PAUSE” mode.
When both “Error counts” and “# of picks” are set “0” (zero) or “Error counts” is set to a
number larger than “# of picks, no warning message is issued.
Note
Note
Note
Note
EUKYX
2-60199-3100
3.1 Auto Ope. Set-up
[5] Noz replace in the lowering of picks
Select "Enable" or "Disable" to change the nozzle automatically to a spare nozzle in the stocker
when the successful component handling rate is lowered during the automatic operation.
(a) The automatic change only for the high-speed nozzle is available.
(b) A spare nozzle should be setup in the stocker in advance.
[6] Feeder Base Up/Down Opn restrictions
Select “Enable” or “Disable” for feeder base Up/Down operation restrictions.
[7] G5S Mode
Select “Enable” or “Disable” for G5S Mode.
Set value Throughput in optimal conditions
Enable 37.5kcph per head
Disable 45.0kcph per head
[8] Mount Mode
It is activated when “Disable“ is selected for G5S Mode. Select the mount mode from below.
Set value Throughput in optimal conditions / Placement accuracy
Standard
42.5kcph per head / ±36 μm (0402)
45.0kcph per head / ±40 μm (0603 or more)
High precision 1 42.5kcph per head / ±36 μm (0402 or more)
High precision 2
40.0kcph per head / ±25 μm (0402 to 0603)
40.0kcph per head / ±36 μm (1005 or more)
Note
EUKYX
2-61199-3100
3.1 Auto Ope. Set-up
Set-up 2
[1]
[2]
[3]
F3B74A
[1] Cutter operation set-up
Block 1, 2
Specify the following items for each cutter operation.
Mode
Select one of the following options to determine whether or not the cutter function should
be used.
Not Cut / After Pick-up(leng des) / At Transfer(leng des) / At Transfer(every time) / Cancel
Length [mm]
Set the length of the tape to be cut by each cutter.
Deceleration
Select one of the following options to determine the rate of the speed reduction.
Full Speed, 10%Decr, 20%Decr, 30%Decr, 40%Decr,
50%Decr, 60%Decr, 70%Decr, 80%Decr, 90%Decr
[2] Side view camera
Block 1, 2
Whether or not the measurement using the side view camera is enabled, is selected in this
data box.
[3] Light Emitter Recog
Block 1, 2
Whether or not the corn recognition is performed automatically per head, is set in this
selection box.
Automatic : When selected, the corn recognition is performed automatically.
Disable : When selected, the corn recognition is not performed.
(a) When the corn recognition function is used, the reference mark recognition is not
available.
(b) It is available when the high-speed head is used.
Note