EUKYX 1-56 199-3100 5.18 T able Offset 5. 1 8 T able O f fset The of fset amount (X, Y) is taught when the head i s m ov ed from the b oard positi oning standa rd to the sp ecified distance. [1] [2] [3] [4] Graphic Devel…

EUKYX
1-55199-3100
5.17 Master Noz Lv (Indv.)
5.17 Master Noz Lv (Indv.)
This window is not displayed when the multi-functional head is selected.
The master nozzle level is taught individually.
[1]
[3]
[2]
Graphic
Development
F3A98
[1] Teaching Data Display Section
The offset value of the specified head is displayed.
[2] [NOZ.CHG.] button
The "NOZ.CHG." window is displayed. The nozzle is changed by operating the window.
[3] Teaching procedures section
The following buttons are arranged in teaching procedures section.
Select head
Select the head to be taught.
[Noz] Button
Specifies the nozzle to be taught.
When the [Nozzle] button is pressed, the data input window appears.
[Noz. place. pos. move] button
Pressing the button turns the specified nozzle to move to the machine front side when
attaching/detaching nozzle.
[Teach Start] button
Starts the teaching.
[Save] button
Saves the teaching results.
• Teaching Procedures
(1) Select the Head (1 or 2) to be taught.
(2) Press the [Noz] button and select the nozzle No. (from 1 through 15) on the [Noz] selection
window.
(3) Press the [Noz place. pos. move] button to attach the master nozzle.
(4) Press the [Teach Start] button.
(5) Press the [Save] button.
Note
Procedure

EUKYX
1-56199-3100
5.18 Table Offset
5.18 Table Offset
The offset amount (X, Y) is taught when the head is moved from the board positioning standard to
the specified distance.
[1]
[2]
[3]
[4]
Graphic
Development
F3A48
[1] Head1/ Head 2 Tabs
When each tab is pressed, the corresponding window of the head for teaching is displayed.
[2] “Teach/Conf” tabs
Switches the "Teach" window and "Conf" window.
[3] Teach/Conf window
The teaching data is displayed when the "Teach" tab is selected.
The confirmation data is displayed when the "Conf" tab is selected.
[4] Teaching procedures section
The following buttons are arranged in teaching procedures section.
Select head
Selects the head to be taught.
[Teach Start] button
Starts the teaching.
[Confirmation] button
Performs the confirmation.
[Save] button
Saves the teaching results.
• Teaching Procedures
(1) Set the jig board on the positioning place.
(2) Select the Head (1 or 2) to be taught.
(3) Press the [Teach Start] button. The teaching results are displayed on the teaching data.
(4) Press the [Confirm] button. The confirmation results are displayed on the confirmation data.
(5) Press the [Save] button.
Procedure

EUKYX
1-57199-3100
5.19 Self Calibration
5.19 Self Calibration
This window is not displayed when the multi-functional head is selected.
The placement accuracy measurement is automatically performed in the machine and the results
are fed back to the offset data.
[1]
[2]
[3] [4]
[7]
[5]
[6]
Graphic
Development
F3A49
[1] Teach Mode / [Teach Start] button
Switches to the program for placement accuracy adjustment.
[2] Measurement Mode / [Accuracy Confirm1], [Accuracy Confirm2]buttons
Switches to the program for placement accuracy confirmation.
[3] Accur.Conf. Result Re-display
Displays the accuracy confirmation result per stage.
[4] Restore
Restores the backed up head offset data per stage.
[5] Setup
Performs the setup of items below required for self calibration
CNVR Set-up, Noz.Chg., PCB Xfer., and Fdr P-u Tch
[6] Cancel
Cancels the teaching.
[7] Teaching procedures section
The following buttons are arranged in teaching procedures section.
Select stage
:
Select stage to be taught.
[USL] button
:
Set the standard value.
[Teach Start] button
:
Start the teaching.
[END] button
:
Finish the teaching.
Note