EUKYX-199-3100_G5S2_Instruction_Vol3_E.pdf - 第130页
EUKYX 1-81 199-3100 6.3 RECOG 6.3 . 2. 2 PEC Reco g Pressi ng the [PEC Recog] sub tab on t he [ Recog L igh t] tab displ ays the fol lowi ng wi ndow . [1] [2] [3] Graphic Development F3A75 [ 1 ] Se lect cam era Us ing th…

EUKYX
1-80199-3100
6.3 RECOG
6.3.2.1 Cmp. Recog
Pressing the [Cmp. Recog] sub tab on the [Recog Light] tab displays the following window.
[1]
[2]
[3]
[4]
Graphic
Development
F3A74
[1] Select camera Buttons
Using these buttons, the component recognition camera to check the component recognition
lighting, is selected.
[2] Select Light Buttons
Using these buttons, the lighting pattern to be checked is selected.
[3] Recognition Lighting Image Display Section
The recognition lighting pattern is changed according to the lighting pattern selected using the "[2]
Recognition Lighting Selection Buttons".
[4] [Cnt. Light ON] Button
When this button is pressed, the recognition lighting selected in [2] is turned ON
continuously.
[Light OFF] Button
The recognition lighting that has been continuously turned ON is turned OFF.
[Odr. Light ON] Button
All of the recognition lighting shown in [2] are turned ON or OFF consecutively.
• Component Recognition Lighting Confirmation Procedure
(1) Select the component recognition camera to confirm with button [1].
(2) Select the lighting pattern to confirm with button [2].
(3) Select the lighting condition with button [4].
(The lamp is turned ON according to the selected lighting condition).
The lamps which currently turn ON, are indicated in yellow.
Procedure
Note

EUKYX
1-81199-3100
6.3 RECOG
6.3.2.2 PEC Recog
Pressing the [PEC Recog] sub tab on the [Recog Light] tab displays the following window.
[1]
[2]
[3]
Graphic
Development
F3A75
[1] Select camera
Using these buttons, the PEC recognition camera to check the PEC recognition lighting, is selected.
[2] Select Light
Using these buttons, the lighting pattern to be checked is selected.
[3] [Light ON] Button / [Light OFF] Button
When this button is pressed, the lighting selected using "[2] Recognition Lighting Selection Buttons"
is turned ON or OFF.
• PEC Recognition Lighting Confirmation Procedure
(1) Using the button [1], select the PEC recognition camera with which the confirmation is to be
performed.
(2)
Using the button [2], select the lighting pattern with which the confirmation is to be performed.
(3) Using the button [3], select the lighting condition and confirm the lighting.
Procedure

EUKYX
1-82199-3100
6.3 RECOG
6.3.3 Capture Img.
Pressing the [Capture Img.] tab on the [RECOG] window displays the following window.
Graphic
Development
F3A76
Sub Tabs
The "Capture Img." window is provided with the following two tabs. When each tab is pressed, the
corresponding tab sheet appears.
Sub tab Description
Cmp. Recog In this tab sheet the image is captured using the
component recognition camera and the trigger line and
camera performance are checked.
PEC Recog In this tab sheet the image is captured using the PEC
recognition camera and the wire connection and camera
performance are checked.