4.3 CONVEYOR
4.3.3 X Axis grease up
Follow the instructions on the window to apply grease to X-axis.
Graphic
Development
F3A95
4.3.4 FDR BASE
The status colors show the connection status of feeder base and feeder.
Graphic
Development
F3A96
EUKYX
1-24199-3100
5. Shipment Adj.
5. Shipment Adj.
In this window, the teaching operations to be performed when the machine is shipped from the
factory, are summarized.
In normal cases, it is not required to perform this teaching operation because the offsets are
factory-adjusted upon shipment of the machine.
Graphic
Development
MTN:NotRdy RCG:NotRdy
Cover
F3A22A
Common Operation Description
F3A23
[Bk.] Button
When this button is pressed, the window for the current items is changed to the one for the
previous Shipment Adjustment items.
As there is no previous items for the "Side View Camera" window, this button is not displayed
on the window.
[Fr.] Button
When this button is pressed, the window for the current items is changed to the one for the next
Shipment Adjustment items.
[Rtn.] Button
When this button is pressed, the window is changed to the one for the shipping adjustment initial
display window.
Notice
Note
EUKYX
1-25199-3100
5. Shipment Adj.
Button Name Teaching Outline
Side View Camera Teaches the side view camera attached to each placement head.
NL-Axis Org Master Noz
Lv
The teaching for avoiding the impact given to the component in the NL-axis
rotation and for the master nozzle lower surface level reference position are
performed.
Chute Lv
The head up/down offset is calculated automatically by teaching the chute
level when the head is changed.
Cmp Recog Light Teaches the lighting for the component recognition camera.
PCB Recog Light Teaches the lighting for the PCB recognition camera.
Mark Light Teaches the Mark Light.
Cmp Recog Mag Teaches the magnification of component recognition camera.
PEC Recog_Beam
Teaches the PEC recognition camera offsets (Magnifications X (Horizontal),
Y (Vertical) and Z (Angle) and the beam offsets (Beam X (Horizontal), Beam
Y (Vertical), Beam Angle X and Beam Angle Y).
Cmp Recog Camr Pos
Teaches the component recognition camera position (X (Horizontal), Y
(Vertical) and Z (Angle) are performed.
Hd Rot Axis Offset
Teaches the designed distance from the locating position reference to the
camera center based on the placement position reference.
Hd Rot Center
Teaches to correct the deviation of the head rotation center from the PEC
recognition camera center reference value using the jig component.
Fly Recog Camr
The image capture timing is taught after finding the deviation of component
recognition camera position in stopped image shooting, from the position in
fry recognition image capturing.
Noz Stk Pos
Teaches for keeping the nozzle stocker position (machine coordinate
reference).
Noz Incln Teaches the offset data to collect the head/nozzle inclination.
Noz Lv/Pos.
Teaches the nozzle lower surface level for the normally attached nozzle and
for the deviation of the head rotation center to the nozzle end position to the
head from the reference values.
Support pin Pos Teaches the PCB support pin position (X-axis, Y-axis).
Master Noz Lv (Indv.) Teaches the master nozzle level individually.
Table
Teaches the deviation amount (X and Y) when the head moves from the
PCB positioning reference to the grid (X and Y).
Self Calibration
Measures placement accuracy in the machine automatically and feeds back
to offset data.
Slit Pos Teaches the slit position on backup base.
The teaching operation might affect the component placement accuracy. Therefore,
contact YAMAHA sales representatives.
Some operations require special jigs (options).
Contact YAMAHA sales representatives before performing any teaching operations.
Follow the teaching procedures in the specified order. Otherwise, some trouble (such as
inaccurate component placement, frequent mechanical errors, etc.) will arise.
Before performing any teaching operation, confirm that the component recognition offset
jig, the jig setting position, and the back light stage (teaching plate) are not nicked and
stained.
Notice