AHB01ESPP *1 *2 2.2 "Message" T ab This tab sheet displays the unit Nos., the step Nos., the feeder Nos., the nozzle Nos., the nozzle IDs, etc., (related to the picked and placed com- ponents) in the pattern pr…

AHB01ESPP
2.1 Zeroing Operation
Follow the steps below to zero each device.
Operation Procedure
(1) Confirm that the machine is set in the "STOP" mode.
(2) Confirm that the front and rear safety doors are closed.
(3) When the [ENABLE] button on the operation panel is pressed in 2
seconds after the [ALL] button (entitled "ZERO"), all devices dis-
played in the "Origin Information" group box of "Origin/Signal Info."
tab sheet are zeroed.
While the devices are being zeroed, "MOVE" is displayed.
2.1 Zeroing Operation
0107-001 5 -6

AHB01ESPP
*1
*2
2.2 "Message" Tab
This tab sheet displays the unit Nos., the step Nos., the feeder Nos., the
nozzle Nos., the nozzle IDs, etc., (related to the picked and placed com-
ponents) in the pattern program.
••
••
• Sheet Layout
When the machine is started or the "Message" tab is pressed in the
"AUTO OPN." window (submenu), the following tab sheet appears in-
side the window.
Fig. 2E4 "Message" Tab Sheet
••
••
• Sheet Composition
*1 Handling/Placement Step
As for the picked or placed components, the following information
will be displayed.
Unit (U) : Unit Nos. of Pattern Program
Place. (P) : Step Nos. of Placement Data (P)
Offset (O) : Step Nos. of Placement Data (O)
Fdr. No. (F) : Nos. of Selected Feeders
Nozzle No : Nos. of Selected Nozzles
Nozzle Id : Types of Selected Nozzles
*2 PCB Prcs. Time
Displayed in the text box is the time (seconds) required to finish one
P.C.B. excluding the P.C.B. in the middle of process.
This is the total time from the P.C.B. transfer start until the X/Y beam
is zeroed after the final component placement.
2.2 "Message" Tab
01 12-002 5-7

AHB01ESPP
2.3 "State" Tab
The corresponding tab sheet displays the number of processed P.C.B.’s
and the management data.
••
••
• Sheet Layout
When the "State" tab is pressed in the "AUTO OPN." window (submenu),
the following tab sheet appears inside the window.
Fig. 2E5 "State" Tab Sheet
••
••
• Sheet Composition
*1 PCB Counter
Displayed in the "Prcs" and "Prod" text boxes are the number of
processed P.C.B.’s (single and unit board).
Prcs : Displayed is the number of all processed P.C.B.’s.
Prod : Displayed is the number of all processed P.C.B.’s (single
boards converted as unit ones.)
*2 [Clear] Button
Pressing this button clears the number of processed P.C.B.’s to "0"
(zero).
*3 Place. (Compl/Total)
The fraction and the percentages are displayed, representing the
current state of component placement.
2.3 "State" Tab
*1
*2 *4
*3
01 12-002 5-8