AHB01ESPP
*8 "Nozzle Polarity Mode" Group Box
When the same library data is used for both Sides A and B, it can be
determined whether or not the polarity nozzles should be used.
[Enable] Button: Production becomes possible, using the same
library data.
[Disable] Button: Production becomes impossible, using the same
library data.
It is required to create the library data separately
and use the data for each production.
Default: [Disable] Button Selected
(a) When the polarity nozzles are used and the same com-
ponents are arranged on both Sides A (Rear Beam)
and B (Front Beam) through component picks, the
same library data may not be used without any modi-
fication. Therefore, it is required to select this nozzle
polarity mode.
(b) Actions taken to pick up a polarity component from
the rear side
A component is picked up after the Z axis of the head
is rotated 180 degrees and it is recognized and placed
as "Component to be recognized with the movable
camera Æ Component picked up from the front side
(the head rotated back by 180 degrees after the
pickup)" or "Component to be recognized with the fixed
camera Æ Component picked up from the rear side".
*9 "Pickup level for embossed Calculation Method" Group Box
The [Ix mode] or the [TIM5000 mode (Standard)] button can be se-
lected to determine the calculation method of the embossed pickup
level.
[Ix mode] Button: The calculation method for TIM-X100 is used.
[TIM5000 mode (Standard)] Button:
The calculation method for the TIM-5000 series
is used.
Default: [Ix mode] Button Selected
There is a difference in the pickup actions (the descending
positions at component picks) for the components (Thick-
ness T
=
Thickness (t)) on the embossed tape between
TIM-X100 and TIM-5000 series.
Therefore, an error such as "excessive pushing" occurs
when the descending position is not specified according to
the selected data.
3.3 "OPN. Mode" Tab
0308-001 5-22-1
Note
Note
AHB01ESPP
Pickup Level for TIM-5000 Series
Because the distance between the reference level of the em-
bossing and the pickup surface must be entered, it is required
to make the manual calculation (Principal Pickup Level + Com-
ponent Thickness (T) - Component Thickness (t)) and enter
the result of the calculation as a pickup level.
Pickup Level for TIM-X100
The distance between the reference level of embossing and
the uppermost surface of the component must be entered.
The component pickup surface (Principal Pickup Level + Com-
ponent Thickness (T) - Component Thickness (t)) is automati-
cally calculated.
*10 "Short Nozzle Mode" Group Box
"Disable" or "Enable" can be selected to determine whether or not
the short nozzles should be handled.
[Disable] Button: Only the standard nozzles can be used.
[Enable] Burron: The short nozzles can be used.
Table 2E2-1
Nozzle Types Standard Short 1 Short 2
Nozzle Length: L 19.0 13.0 11.0
Applicable Thickness 0 to 5.0 5.0 to 11.0 7.0 to 13.0
of Component
Nozzle ID E*** D*** C***
(Example: EA06) (Example: DA06) (Example: CA06)
*11 [Prev] Button
When pressed, this button opens the first page.
3.3 "OPN. Mode" Tab
0308-001 5-22-2
AHB01ESPP
3.4 "Test Run" Tab
The corresponding tab sheet enables the operator to specify a test op-
eration.
Sheet Layout
When the "Test Run" tab is pressed in the "OPN. MODE" window
(submenu), the following tab sheet appears inside the window.
Fig. 2E14 "Test Run" Tab Sheet (Provided with Multi-Layer Tray Feeder 2)
The tab sheet may look different, depending on which options
are selected.
Sheet Composition
*1 TEST PATTERN
When the drop-down arrow (located at the right side of the drop-
down list box) is pressed, the drop-down list opens. Select the pat-
tern to be set as a test run.
*2 Test Run
Make a combination of the following functions as a test mode.
The following buttons are provided.
[Comp. Missing Dsbl.] Button
[Vacuum Sensor Err. Dsbl.] Button
[Comp. Vertical Dsbl.] Button
[P.C.B. Location Dsbl.] Button
3.4 "Test Run" Tab
*1
*2
*3
0308-004 5-23
Note