2OM-1075-002.pdf - 第286页

AHB01ESPP 4.1.1 "P .C.B. T ransfer Adj." T ab The corresponding tab sheet enables the operator to change the setting of the conveyor timer and conduct a performance test. Parameters can be specified for each co…

100%1 / 469
AHB01ESPP
4.1 "Conveyor Adj" Tab
The corresponding tab sheet enables the operator to activate the con-
veyor motors.
Sheet Layout
When the "Conveyor Adj" tab is pressed in the "UNIT ADJ." window
(submenu), the following tab sheet appears.
Fig. 2F42 "Conveyor Adj" Tab Sheet
Sheet Composition
*1 Tabs and Tab Sheets
The "Conveyor Adj" tab sheet is provided with the following 3 tabs.
When a tab is pressed, the corresponding tab sheet appears inside
the window.
Table 2F6
Tabs Description
P.C.B. Transfer Adj. The corresponding tab sheet enables the operator to
conduct a performance test according to the data speci-
fied in the "Xfr Prmtr Adj" tab sheet.
PCB Lct Sol Adj The corresponding tab sheet enables the operator to
activate the P.C.B. locate solenoid.
PCB Xfr Adj The corresponding tab sheet enables the operator to
activate the conveyor motors.
0308-004 6-53
4.1 "Conveyor Adj" Tab
*1
AHB01ESPP
4.1.1 "P.C.B. Transfer Adj." Tab
The corresponding tab sheet enables the operator to change the setting
of the conveyor timer and conduct a performance test.
Parameters can be specified for each conveyor in the "Xfr Prmtr Adj"
tab sheet.
Sheet Layout
When the "P.C.B. Transfer Adj." tab is pressed in the "Conveyor Adj" tab
sheet, the following tab sheet appears.
Fig. 2F43 "P.C.B. Transfer Adj." Tab Sheet
Sheet Composition
*1 "Operation" Group Box
The following buttons are provided in this group box.
[Transfer In-Cnvr Buffer Posn] Button
When the [ENABLE] button on the operation panel is pressed
in 2 seconds after this button is selected and the [ON] button
(entitled "MOVE") is pressed, the P.C.B. is transferred to the
input conveyor buffering position.
[Transfer PCB Locate Posn] Button
When the [ENABLE] button on the operation panel is pressed
in 2 seconds after this button is selected and the [ON] button
(entitled "MOVE") is pressed, the P.C.B. is transferred to the
P.C.B. locate position.
0308-004 6-54
4.1 "Conveyor Adj" Tab
*1
*2
*3
*6
*5
*4
AHB01ESPP
[Transfer P-Cnvr Buffer Posn] Button
When the [ENABLE] button on the operation panel is pressed
in 2 seconds after this button is selected and the [ON] button
(entitled "MOVE") is pressed, the P.C.B. is transferred to the P-
conveyor buffering position.
[Transfer Out-Cnvr Buffer Posn] Button
When the [ENABLE] button on the operation panel is pressed
in 2 seconds after this button is selected and the [ON] button
(entitled "MOVE") is pressed, the P.C.B. is transferred to out-
put conveyor buffering position.
[PCB Locate] Button
When the [ENABLE] button on the operation panel is pressed
in 2 seconds after this button is selected and the [ON] button
(entitled "MOVE") is pressed, the back up base moves up to
the P.C.B. positioning position.
[PCB Unlocate] Button
When the [ENABLE] button on the operation panel is pressed
in 2 seconds after this button is selected and the [ON] button
(entitled "MOVE") is pressed, the back up base moves down to
its origin.
*2 [P.C.B. locate Sequence] Button
Select one of the following options as a P.C.B. positioning sequence.
Standard: Y Clamp deactivated, Z Clamp activated, and BPC Axis
activated
Z clamp & Y Pusher: Y Clamp activated once, Z Clamp activated,
and BPC Axis activated
*3 "B.P.C. Adj" Group Box
The following buttons are provided in this group box.
[PCB Thickness] Button
When this button is pressed, the "PCB Thickness" edit win-
dow opens.
Enter a parameter as the thickness of the P.C.B. to be trans-
fer-tested in the range of 0 to 50 mm.
The P.C.B. thickness in the current pattern program is set
as a default one.
Enter "5 mm" when the current pattern program is not speci-
fied.
0308-003 6-55
4.1 "Conveyor Adj" Tab
Note