2OM-1075-002.pdf - 第218页
AHB01ESPP 7.3.1.2 "PCB Lct Sol Adj" T ab Sheet This tab sheet enables the operator to activate the P .C.B. locate sole- noid. • • • • • Sheet Layout When the "PCB Lct Sol Adj" tab is pressed in the &q…

AHB01ESPP
[Transfer Out-Cnvr Buffer Posn] Button
When the [ENABLE] button on the operation panel is pressed in
2 seconds after this button is selected and the [ON] button (en-
titled "MOVE") is pressed, the P.C.B. is transferred to output
conveyor buffering position.
[PCB locate] Button
When the [ENABLE] button on the operation panel is pressed in
2 seconds after this button is selected and the [ON] button (en-
titled "MOVE") is pressed, the B.P.C. moves up to the P.C.B.
locate position.
[PCB unlocate] Button
When the [ENABLE] button on the operation panel is pressed in
2 seconds after this button is selected and the [ON] button (en-
titled "MOVE") is pressed, the B.P.C. moves down to its origin
position.
[Move B.P.C. to PCB Locate Posn] Button
When the [ENABLE] button on the operation panel is pressed in
2 seconds after this button is selected and the [ON] button (en-
titled "MOVE") is pressed, the B.P.C. moves to its positioning
section.
[Move B.P.C. to Standby Posn] Button
When the [ENABLE] button on the operation panel is pressed in
2 seconds after this button is selected and the [ON] button (en-
titled "MOVE") is pressed, the B.P.C. moves to its standby posi-
tion.
The standby position is specified in the current pattern pro-
gram.
[Zero B.P.C.] Button
When the [ENABLE] button on the operation panel is pressed in
2 seconds after this button is selected and the [ON] button (en-
titled "MOVE") is pressed, the B.P.C. moves to its origin posi-
tion.
*2 "Control Sw" Group Box
When the [ENABLE] button on the operation panel is pressed in 2
seconds after one of the buttons in the "Operation" group box (*1) is
selected and the [ON] button (entitled "MOVE") is pressed, the ac-
tion corresponding to the selected button takes place.
••
••
• Operation Procedure
(1) Set parameters in the "Xfr Prmtr Adj" tab sheet.
(2) Select one of the buttons in the "Operation" group box (*1).
(3) Press the [ON] button (entitled "MOVE"). In 2 seconds, press the
[ENABLE] button on the operation panel.
7.3 "PCB Support Pins Set-up Mode" Tab
Note
0206-001 5-54-1

AHB01ESPP
7.3.1.2 "PCB Lct Sol Adj" Tab Sheet
This tab sheet enables the operator to activate the P.C.B. locate sole-
noid.
••
••
• Sheet Layout
When the "PCB Lct Sol Adj" tab is pressed in the "Conveyor Adj" win-
dow, the following tab sheet appears.
Fig. 2E46 "PCB Lct Sol Adj" Tab Sheet
••
••
• Sheet Composition
*1 "Operation" Group Box
The following buttons are provided in this group box.
Select one of the following buttons.
[Stopper] Button
When pressed, this button activates P.C.B. Stopper P1 or P2.
[Width near] Button
When pressed, this button narrows the conveyor width, using
the P.C.B. YL or YR pusher.
[Clamp] Button
When pressed, this button activates the P.C.B. ZL or ZR clamp.
7.3 "PCB Support Pins Set-up Mode" Tab
*1
*4
*2
*3
0206-002 5-55

AHB01ESPP
*2 "Up and Down Control" Group Box
The following buttons are provided in this group box.
The contents of the sheet differ, depending on the button selected in
the "Operation" group box (*1).
Unit Buttons
[Stopper] Button Selected : [P1], [P2]
[Width near] Button Selected : [YL], [YR]
[Clamp] Button Selected : [ZL], [ZR]
Control Buttons
[Stopper] Button Selected : [Upward] and [downward] Buttons
[Width near] Button Selected : [Clamp ON] and [Clamp OFF]
Buttons
[Clamp] Button Selected : [Clamp ON] and [Clamp OFF]
Buttons
*3 "Time" Group Box
When the [Stopper] button is selected in the "Operation" group box
(*1), the periods of time required for upward and downward move-
ment on the L and R sides.
When the [Width near] or the [Clamp] button is selected in
the "Operation" group box (*1), the "Time" group box (*3)
disappears.
*4 "Control Sw" Group Box
When the [ENABLE] button on the operation panel is pressed in 2
seconds after some buttons in "*1" and "*2" are selected and the
[ON] button (entitled "MOVE") is pressed, the action corresponding
to the selected buttons takes place.
••
••
• Operation Procedure
(1) Select one of the buttons in the "Operation" group box (*1).
(2) Select one of the unit buttons and press the desired control button
in the "Up and Down Control" group box (*2).
(3) Press the [ON] button (entitled "MOVE"). In 2 seconds, press the
[ENABLE] button on the operation panel.
7.3 "PCB Support Pins Set-up Mode" Tab
Note
0206-001 5-55-1