2OM-1075-002.pdf - 第243页
AHB01ESPP *4 "Speed" Group Box Set the time during which the X/Y beam should stay still at the place- ment point. When the button in the group box is pressed, the label changes in scrolling such as "High S…

AHB01ESPP
3.1 "X/Y Beam Test" Tab
The corresponding tab sheet enables the operator to check the X/Y beam
movement according to the current pattern program.
The P.E.C. recognition camera captures an image of the placement
position in the order of the pattern programs.
••
••
• Sheet Layout
When the "X/Y Beam Test" tab is pressed in the "DVC. TEST" window
(submenu), the following tab sheet appears.
Fig. 2F7-1 "X/Y Beam Test" Tab Sheet
••
••
• Sheet Composition
*1 Crnt. Prgm.
Displayed is the currently selected pattern program name.
*2 Recognized Image
The image of the recognized P.C.B. is displayed.
When this area is pressed, the recognized image disappears.
*3 Head
Displayed is the head No. specified in the pattern program.
3.1 "X/Y Beam Test" Tab
*1
*9
*3
*5
*7
*8
*2
*4
*6
0206-001 6-12-1

AHB01ESPP
*4 "Speed" Group Box
Set the time during which the X/Y beam should stay still at the place-
ment point.
When the button in the group box is pressed, the label changes in
scrolling such as "High Speed" Æ "Mid. Speed" Æ "Low Speed".
High Speed : 50 msec
Mid. Speed : 1000 msec
Low Speed : 2000 msec
*5 "Operation Mode" Group Box
[Auto] Button
When this button is selected and the [ENABLE] button on the
operation panel is pressed in 2 seconds after the [ON] button
(entitled "MOVE"), the X/Y beam moves in succession according
to the pattern program.
[Step] Button
When this button is selected and the [ENABLE] button on the
operation panel is pressed in 2 seconds after the [ON] button
(entitled "MOVE"), the X/Y beam moves step by step according to
the pattern program.
*6 "Others" Group Box
[PCB Xfr Mnl Mode] Button
When pressed, this button opens the "PCB Xfr Mnl Mode" sheet.
(Not available at present)
[Zero XY Beam] Button
When this button is selected and the [ENABLE] button on the
operation panel is pressed in 2 seconds after the [ON] button
(entitled "MOVE"), the X/Y beam starts returning to its origin (ze-
roing).
*7 "Step No." Group Box (Step Designation)
Press one of the following buttons. The edit window opens. Desig-
nate the step No. in the pattern program with which an X/Y beam
test must be started.
[U-NO] Button : When this button is pressed, the corresponding
edit window opens. Designate the step No. (U-
No.).
[P-NO] Button : When this button is pressed, the corresponding
edit window opens. Designate the step No. (P-
No.).
[O-NO] Button : When this button is pressed, the corresponding
edit window opens. Designate the step No. (O-
No.).
3.1 "X/Y Beam Test" Tab
0206-001 6-12-2

AHB01ESPP
*8 Fdr. No.
Displayed is the data of the step No. designated in "*7".
*9 "Control SW" Group Box
When the [ON] button (entitled "STOP") is pressed during the X/Y
beam test, the X/Y beam moves as far up as to the last step of the
pattern program, returns to its origin, and stops.
When the [ENABLE] button on the operation panel is pressed in 2
seconds after the [Auto] button or the [Step] button is selected and
the [ON] button (entitled "MOVE") is pressed, the X/Y beam moves
in succession or step by step according to the pattern program.
When the [ENABLE] button on the operation panel is pressed in 2
seconds after the [Zero XY Beam] button is selected and the [ON]
button (entitled "MOVE"), the X/Y beam starts returning to its origin
(zeroing).
••
••
• Procedure for X/Y Beam Test
(1) Set the current pattern program to be tested.
(2) To specify the starting step, designate it in the "Step No." group box
(*7).
(3) Set the period of time during which the X/Y beam stays still at the
placement point, using the button in the "Speed" group box (*4).
(4) Specify how to move the X/Y beam in the "Operation Mode" group
box (*5).
[Auto] Button : The XY beam moves in succession according
to the pattern program.
[Step] Button : The XY beam moves step by step according to
the pattern program.
(5) Start the X/Y beam test.
Selection of [Auto] Button
••
••
• When the [ENABLE] button on the operation panel is pressed in 2
seconds after the [ON] button (entitled "MOVE"), the X/Y beam
moves in succession according to the pattern program.
When the [ON] button (entitled "STOP") is pressed during the X/Y
beam test, the X/Y beam moves as far up as to the last step of the
pattern program, returns to its origin, and stops.
Selection of [Step] Button
••
••
• Every time the [ENABLE] button on the operation panel is pressed
in 2 seconds after the [ON] button (entitled "MOVE"), the X/Y beam
moves step by step.
3.1 "X/Y Beam Test" Tab
0206-001 6-12-3