2OM-1075-002.pdf - 第421页
AHB01ESPP *2 "Select Feeder Base" Group Box Select the feeder base to be used for teaching operations. The following buttons are provided in this group box. [Feeder Base 1], [Feeder Base 3], and [Feeder Base 4]…

AHB01ESPP
5.15 "Feeder Base Ofs" Tab
The corresponding tab enables the operator to perform the teaching
operation on the feeder base offset data.
The deviations (offsets) from the design position can be determined by
recognizing the round marks on the feeder bases.
This teaching operation must be performed only by our service
personnel.
• Sheet Layout
When the "Feeder Base Ofs" tab is pressed in the "TEACHING" window
(submenu), the following tab sheet appears inside the window.
Fig. 2F122 "Feeder Base Ofs" Tab Sheet (Provided with Multi-Layer Tray Feeder 2)
The tab sheet may look different, depending on which options
are selected.
• Sheet Composition
*1 "Select Head" Group Box
Select the P.E.C. recognition camera to be used for teaching opera-
tions.
The following buttons are provided in this group box.
[X1 Head] and [X2 Head] Buttons
5.15 "Feeder Base Ofs" Tab
Note
0206-002 6-186
Note
*1
*2
*3
*5
*9
*8
*7
*6
*10
*4

AHB01ESPP
*2 "Select Feeder Base" Group Box
Select the feeder base to be used for teaching operations.
The following buttons are provided in this group box.
[Feeder Base 1], [Feeder Base 3], and [Feeder Base 4] But-
tons
*3 "Select Mark" Group Box
[Mark] Button
Select this button for automatic recognition.
Select this button in normal cases.
[Feeder] Button
This button is not used in normal cases.
*4 "Selection of Teaching Operation" Group Box
The following buttons are provided in this group box.
[All Beams (Incl. NC Axis) Heads Zero] Button
When this button is pressed, all X/Y beams are zeroed.
[Teach Start] Button
When this button is pressed, a teaching operation is performed
on the selected feeder base.
*5 Offset Values
Displayed are the current values and the adjusted ones after teach-
ing.
*6 Set Status
When the "P.E.C. Dsbl." or the "Comp. Recognition Dsbl." check
box in the "Test Run" window is turned on (checked), the background
color of "Recognition Dsbl." turns light red. (No background color in
normal cases).
No recognition processing is made even if a teaching op-
eration is performed when the each check box is turned on
(checked) in the "Test Run" window. Therefore, various
teaching operations will get incorrect results.
When "All Beam (Incl. NC Axis) Heads Zero" is completed, the back-
ground color of "All Beam Zero" turns green. (Otherwise, the back-
ground has no color.)
(a) When each device is not zeroed and the teaching op-
erations are performed, note that the offset values may
not be taught correctly.
(b) Before performing a teaching operation, be sure to zero
all beams.
Note
Note
0206-002 6-187
5.15 "Feeder Base Ofs" Tab

AHB01ESPP
*7 [Clear Adj.] Button
When pressed, this button clears the results of the teaching opera-
tion.
*8 [Cancel] Button
When pressed, this button ends the teaching operation without re-
flecting the teaching results on the offset data.
*9 [End] Button
When pressed, this button reflects the results of the teaching op-
eration on the offset data and exits from this session.
*10 "Control Switch" Group Box
Select the items (buttons) to be taught and press the [ON] button
entitled "MOVE". After that, press the [ENABLE] button on the op-
eration panel in 2 seconds. A teaching operation is performed on
the selected item.
0206-002 6-188
5.15 "Feeder Base Ofs" Tab