2OM-1075-002.pdf - 第187页

AHB01ESPP (1 1) T o formally (not temporarily) register the new placement coordi- nates, press the [End] button (*1 1). The "Confirmation to Saving" dialog box appears. T o replace the current pattern program d…

100%1 / 469
AHB01ESPP
Case: Diagonal 2-Point Teaching
Fig. 2E23-10 Teaching Operation for "2-Point Teaching"
(9) When the teaching is completed, new placement coordinates are
displayed in the "X (mm)" and "Y (mm)" text boxes of "Teach Result"
(*3).
(10) To temporarily register the new placement coordinates, press the
[Temp Entry] button (*4).
The new placement coordinates are written in a temporary file.
"Temp Entry" appears in place of "Current Value" (*3).
(a) When the new placement coordinates are registered tem-
porarily, the data for operations and the contents in the
temporary file (one of the files used for the current pattern
program) are re-written but the contents of the original file
are not.
(b) While the steps are being registered temporarily, the can-
cel operation is available to cancel the temporary registra-
tion of the data.
To cancel the registration, select the objective step and
press the [Cancel] button (*10).
(c) As for the step being registered temporarily, the background
color in the step data area turns blue.
(d) The temporarily registered data is reflected immediately
upon the automatic (continuous) and step operations.
0308-002 5-25-26
Teaching
Determination of Position
The determined position is
indicated by a blue cross.
Center of Window
Not displayed in actual cases.
The distance is determined based
on the center of the window.
C=P1 X=OOO Y=OOO
5.4 "Place Pos Teach" Tab
Note
AHB01ESPP
(11) To formally (not temporarily) register the new placement coordi-
nates, press the [End] button (*11).
The "Confirmation to Saving" dialog box appears.
To replace the current pattern program data with the new
one (Save)
When the [YES] button is selected in the "Confirmation to Sav-
ing" dialog box, the pattern program data is replaced with the
temporarily saved one.
Fig. 2E23-11 "Confirmation to Saving" Dialog Box
To keep the current pattern program data unchanged
(Save As)
When the [NO] button is selected in the "Confirmation to Sav-
ing" dialog box, the "Input File Name" dialog box opens.
Enter a new file name and press the [Set] button.
The temporarily saved pattern program data is saved in a new
file having the newly entered name.
To discard the taught data (Cancellation of All Taught Data)
Press the [NO] button in the "Confirmation to Saving" dialog
box.
0308-002 5-25-27
5.4 "Place Pos Teach" Tab
AHB01ESPP
6. "RECALL" Window (Submenu)
This window enables the operator to recall the device errors and ma-
chine information that occurred or was issued in the past.
Window Layout
When the [RECALL] button on the submenu bar is pressed, the follow-
ing window (submenu) opens.
Fig. 2E24 "RECALL" Window (Submenu)
0308-004 5-26
6. "RECALL" Window (Submenu)
*1