2OM-1075-002.pdf - 第281页
AHB01ESPP *3 "Data Save" Group Box Enter the name of the file to be saved in the "File Name" text box and press the [FD Save] button. The recognized image is saved on a floppy disk in accordance with …

AHB01ESPP
3.3.3 Save Operation of Recognized Image
• Window Layout
When the [Recog Image Save] button is pressed in the "Cmpnt Recog
Test" tab sheet, the following "Recog Image Save" operation window
appears.
Fig. 2F38 "Recog Image Save" Operation Window
• Window Composition
*1 Comp ID, Recog Error ID, Description, Item
Displayed are the results of a component recognition test.
*2 "Save Mode" Group Box
One of the following modes can be selected as a save mode.
[Not Save] Button : When this button is pressed, the rec-
ognized image is not saved.
[Save (OK)] Button : When the test results in "Good" (Nor-
mal) and this button is pressed, the rec-
ognized image is saved.
[Save (NG)] Button : When the test results in "No Good" (Ab-
normal) and this button is pressed, the
recognized image is saved.
[Save (OK/NG)] Button : When this button is pressed, the rec-
ognized image is saved regardless of
the test results (Normal/Abnormal).
0206-003 6-48
3.3 "Cmpnt Recog Test" Tab
*1
*2
*4
*3

AHB01ESPP
*3 "Data Save" Group Box
Enter the name of the file to be saved in the "File Name" text box and
press the [FD Save] button. The recognized image is saved on a
floppy disk in accordance with the save mode specified in "*2".
*4 [Return] Button
When this button is pressed, the "Cmpnt Recog Test" tab sheet
appears.
0206-003 6-49
3.3 "Cmpnt Recog Test" Tab

AHB01ESPP
3.3.4 Display of Detailed Error Data
• Window Layout
When the [Error Data] button is pressed in the "Cmpnt Recog Test" tab
sheet, the following "Error Data" window appears.
Fig. 2F39 "Error Data" Window
• Window Composition
*1 Error History
Displayed are the details of errors.
*2 [Return] Button
When this button is pressed, the "Cmpnt Recog Test" tab sheet
resumes.
0206-003 6-50
3.3 "Cmpnt Recog Test" Tab
*1
*2