2 Operational Safety User Manual SIPLACE CA 2.9 Residual Voltages and Discharge Times Edition 08/2011 EN 100 2.9.1.2 Residual V olt ages and Discharge T imes after Switc hing off at the Main Switch 2 CAUTION 2 T o avo id…

User Manual SIPLACE CA 2 Operational Safety
Edition 08/2011 EN 2.9 Residual Voltages and Discharge Times
99
Fig. 2.9 - 2 Measuring points on the power supply unit
2
2.9.1.1 Operating Voltages, Residual Voltages and Discharge Times after Pressing
the EMERGENCY STOP Button
2
2
Pins X11 and X13_1
measured to X12 (GND)
Voltage in
normal mode
Residual voltage
after EMERGENCY
STOP
Discharge
times
X11 + 250 VDC < 10 VDC 7 s
X13_1 + 145 VDC < 10 VDC 50 s
Pin X13_4
measured to pin X3_7 (-)
Voltage in
normal mode
Residual voltage
after EMERGENCY
STOP
Discharge
times
X13_4 + 40 VDC + 40 VDC -

2 Operational Safety User Manual SIPLACE CA
2.9 Residual Voltages and Discharge Times Edition 08/2011 EN
100
2.9.1.2 Residual Voltages and Discharge Times after Switching off at the Main Switch
2
CAUTION 2
To avoid losing data, assess the following criteria before switching off your automatic placement
system (apart from in emergencies):
– Has the placement system finished transmitting machine, setup and panel data?
– Has the placement system finished processing the PCB?
– Has the placement system completed the run-up phase?
Pins X11, X13_1 and X13_4
measured to X12 (GND)
Residual voltages when
main power switch is off Discharge times
X11 < 10 VDC < 7 s
X13_1 < 10 VDC < 50 s
X13_4 < 10 VDC < 2 s

User Manual SIPLACE CA 2 Operational Safety
Edition 08/2011 EN 2.10 Disabling the Compressed Air Supply and Discharging the Pressure
101
2.10 Disabling the Compressed Air Supply and Dis-
charging the Pressure
The operating pressure of the machine and SWS is fixed to ± 0.025 MPa (5.0 ± 0.25 bar). The
position of the compressed air unit is shown by item 1 of the fig. 2.10 - 1
. You can interrupt the
flow of compressed air to the machine with the shutoff valve (item 2 of the fig. 2.10 - 1
).
The SWS is supplied with compressed air via the machine.
Use the machine key to release the cover lock.
Lift the cover (see fig. 2.10 - 1).
Turn the handle of the shutoff valve (item 1 of the fig. 2.10 - 1) from vertical to horizontal po-
sition.
Observe the operating pressure manometer (item 5 of the fig. 2.10 - 1). When the automatic
placement system is switched on, the pressure discharges to 0 MPa (0 bar) within 1 minute.
CAUTION
When the machine is switched on, do not use the stop valve to interrupt the compressed air sup-
ply for more than 30 minutes. If you need to shut off the pneumatic system for longer in order to
carry out preventive maintenance or servicing work, you must switch the placement system off at
the main switch and disconnect it from the power supply.