00195941-03-UM SiplaceCA-EN.pdf - 第291页

User Manual SIPLACE CA 4 Setting Up and Commissioning Edition 08/2011 EN 4.5 Setting Up the Placement Machine 291 4.5.9 Fitting the Input Conveyor 4.5.9.1 T ools – Allen keys, DIN 91 1, set – Phillips screwdriver , size …

100%1 / 508
4 Setting Up and Commissioning User Manual SIPLACE CA
4.5 Setting Up the Placement Machine Edition 08/2011 EN
290
4.5.8.5 Fitting the Axis Unit
Carefully lift the axis unit onto the rail in the extension kit.
Make sure that you do not squash any cables.
Push the axis unit into the extension kit as far as the stop.
Secure the axis unit with the fillister head screw.
Insert the cover.
Fasten the ground cable to the door (item 2 in fig. 4.5 - 8, page 280), as shown in fig. 4.5 - 10
on page 284
.
Lock the doors.
4.5.8.6 Fitting the Side Plates
Fasten the ground cable to each side plate (item 6 in fig. 4.5 - 8, page 280), as shown in fig.
4.5 - 10
, page 284.
Fix the side plate to the machine frame with 6 fillister head screws.
NOTE 4
If the input conveyor has been dismantled , continue with section 4.5.9
" Fitting the Input Con-
veyor" on page 291.
If the input conveyor is fitted, continue assembly work with section 4.5.14
"Fitting the Main Fault
Indicator" on page 311.
User Manual SIPLACE CA 4 Setting Up and Commissioning
Edition 08/2011 EN 4.5 Setting Up the Placement Machine
291
4.5.9 Fitting the Input Conveyor
4.5.9.1 Tools
Allen keys, DIN 911, set
Phillips screwdriver, size 1
4.5.9.2 Setting Up
4
Fig. 4.5 - 14 Input conveyor - dual conveyor
(1) Side panel, input conveyor
(2) Side panel, processing conveyor 1
(3) Cable cover 20 x 200
(4) Countersunk screw, ISO 7046, M3x6, 2x per cable cover
(5) Cable cover 20 x 310
(6) Fillister head screw DIN 912, M3x5, 1x per cable cover
(7) Fillister head screw DIN 912, M6x16, and washer, 4x per panel
(8) Hexagonal shaft guidance
(9) Hexagonal shaft (single conveyor: one, dual conveyor: two)
(10)Drive unit
4 Setting Up and Commissioning User Manual SIPLACE CA
4.5 Setting Up the Placement Machine Edition 08/2011 EN
292
Dismantle the cable covers (item 3 and 5 in fig. 4.5 - 14) of the input conveyor (item 1 in fig.
4.5 - 14
).
Place the side (item 1 in fig. 4.5 - 14) carefully on the side of the processing conveyor (item
2 in fig. 4.5 - 14
).
CAUTION 4
Be careful not to cut through any of the light barrier or drive motor cables.
Fasten each side with 4 fillister head screws M6x16 and the corresponding discs (item 7 in
fig. 4.5 - 14
).
Connect the power cable to the light barriers and drive motors.
Fasten the cable covers (item 3 and 5 in fig. 4.5 - 14).
Insert the hexagonal shaft (item 9 in fig. 4.5 - 14) into the drive unit (item 10 in fig. 4.5 - 14).
Make sure that the hexagonal shaft guidance (item 8 in fig. 4.5 - 14) is always pointing to-
wards the conveyor side on which the drive unit (item 10 in fig. 4.5 - 14
) is fixed.