00195941-03-UM SiplaceCA-EN.pdf - 第445页
User Manual SIPLACE CA 7 Station Enlargements Edition 08/2011 EN 7.1 Nozzle Changer 445 7.1.3.7 Changing a Magazine T o remove the magazine, simp ly push the spring hook (item 1 in fig. 7.1 - 16 ) away from the magazin…

7 Station Enlargements User Manual SIPLACE CA
7.1 Nozzle Changer Edition 08/2011 EN
444
7.1.3.6 Operation
When you fill a magazine with a certain nozzle type for the first time, attach an adhesive label
to identify the type.
NOTE 7
Fill the magazines off the machine and always replace complete magazines. 7
Open the locking plate and place the nozzles in the nozzle holders.
Close the locking plate so that the nozzles cannot drop out of the magazines.
CAUTION 7
Magazines may only be filled if all the nozzles on the Collect&Place CA head have been
placed back in their magazines. 7
Programming the nozzle changer is described in the SIPLACE Pro user manual.
NOTE 7
Avoid letting components drop onto the magazines. This can cause the locking plate to jam.
Avoid letting components drop onto the free locations of the feeders. The components could
stick to the magnetic strips. Production may have to be interrupted if the feeder modules are
not placed on the component table correctly. You should therefore regularly clean the maga-
zines and free locations.

User Manual SIPLACE CA 7 Station Enlargements
Edition 08/2011 EN 7.1 Nozzle Changer
445
7.1.3.7 Changing a Magazine
To remove the magazine, simply push the spring hook (item 1 in fig. 7.1 - 16) away from the
magazine. Lift the magazine out of the carrier.
7
Fig. 7.1 - 16 Changing a magazine
(1) Spring hook
(2) Retaining clamp
(3) Centering hole
(4) Slot
(A) Push the spring hook away from the magazine

7 Station Enlargements User Manual SIPLACE CA
7.1 Nozzle Changer Edition 08/2011 EN
446
NOTE
The magazine must be inserted so that the centering pins can slide into the centering hole
(item 3 in fig. 7.1 - 16) and slot (item 4 in fig. 7.1 - 16). 7
First place the side of the magazine with the numbered nozzles 1, 2, 3 and 4 on the base.
The retaining clamp (item 2 in fig. 7.1 - 16
) must slide into the magazine slit.
Push the spring hook away from the magazine.
Press the magazine so that it lies flat on the base, then release the spring hook. The spring
hook must latch into place.
7.1.3.8 Position Detection
Every magazine of the nozzle changer has a positioning fiducial for position detection.
7
Fig. 7.1 - 17 Nozzle changer - Position detection
(1) Position fiducial
(2) Position of the nozzles in the magazine in relation to the position fiducial