00195941-03-UM SiplaceCA-EN.pdf - 第363页

User Manual SIPLACE CA 5 Tasks on the Machine Edition 08/2011 EN 5.8 Changing Setups 363 5.8 Changing Setup s 5.8.1 Changing Setups at the Placement Machine 5.8.1.1 Printing Setup Changeover Instructions Before Setup Cha…

100%1 / 508
5 Tasks on the Machine User Manual SIPLACE CA
5.7 LCD and Status Display at the X-Feeder Module Edition 08/2011 EN
362
5
NOTE 5
Remove the component tape before a reference run.
Reference o
Reference o
Red Position information is no
longer available for the com-
ponent tape drive
Remove the component tape (tape can be
moved out by pressing the arrow keys or
pulled out after raising the pickup window).
Then press the "FOIL" button to start the
reference run.
CAN BusError
(CAN Bus error)
Red CAN bus error Log off and on again, check the optical fiber
interface
ParNotSaved! Red Parameters were not saved Default parameters are loaded automatical-
ly, i.e. the most recent operator settings are
overwritten -> The settings (e.g. increment)
will have to be made again. Replace the
control board if this error occurs frequently.
ParWrongSave Red Wrong or incomplete param-
eters were saved
BootFlashErr
FlashDataErr
Red Can no longer write to boot
or application memory cor-
rectly
Replace the feeder module or control board
Text on the
LCD display
Status
display
Meaning Troubleshooting
User Manual SIPLACE CA 5 Tasks on the Machine
Edition 08/2011 EN 5.8 Changing Setups
363
5.8 Changing Setups
5.8.1 Changing Setups at the Placement Machine
5.8.1.1 Printing Setup Changeover Instructions Before Setup Changes
Before a change of setup, print out the conversion instructions on the printer for the SIPLACE Pro
computer as described in the "SIPLACE Pro" manual or in the online help.
5.8.1.2 What You Should Note when Changing the Feeder Modules
Handle the feeder modules carefully when you insert them into or remove them from the com-
ponent feeder table. Do not hit the X feeder against the centering bar (see item 5 in fig. 5.5 -
3, page 353) of the changeover table.
Vacuum the supporting surfaces of the feeder modules and clean the surface of the compo-
nent feeder table when necessary according to the instructions in the Preventive Mainte-
nance Manual.
Remove loose components using a brush or a vacuum cleaner with a suitable nozzle.
CAUTION 5
Avoid removing components from the component table with your fingers. You may hurt your-
self with tiny splinters of metal.
5 Tasks on the Machine User Manual SIPLACE CA
5.8 Changing Setups Edition 08/2011 EN
364
5.8.2 Changing Setups at the SWS
Check if the orientation of the wafer locking bar fits with the relevant wafer size (10,5" oder
10,8" bei 8" Wafern) (see fig. 3.7 - 19
, page168).
NOTE 5
During commissioning, the SWS is configured according to the required wafer size (8" or 12")
and thickness of the wafer frame. Adapting the SWS to other sizes and thicknesses is de-
scribed in the service manual.
Adjust the feeder plate for the wafer magazine (8" or 12") and insert the new magazine. Make
sure the magazine has the correct configuration.
Check the needle configuration at the die ejector (see section 5.2.5, page 338).
Check, if the flip unit is equipped with the appropriate tools and nozzles (see section 5.2.6,
page 342).
Load or compile the required product (see software guide).