User Manual SIPLACE CA 2 Operational Safety Edition 08/2011 EN 2.11 Energy State after Switching Off at the Main Switch 109 2 Fig. 2.1 1 - 5 Power supply unit, back view X100 Cable connection terminal for the power suppl…

2 Operational Safety User Manual SIPLACE CA
2.11 Energy State after Switching Off at the Main Switch Edition 08/2011 EN
108
2
Fig. 2.11 - 4 Power supply unit, front view
Q1 Main power switch
X102 Service socket
F1 Fuse for the service socket

User Manual SIPLACE CA 2 Operational Safety
Edition 08/2011 EN 2.11 Energy State after Switching Off at the Main Switch
109
2
Fig. 2.11 - 5 Power supply unit, back view
X100 Cable connection terminal for the power supply cable
L20 Discharge reactor with fuses F21, F22 and F23
Z1 Line filter

2 Operational Safety User Manual SIPLACE CA
2.11 Energy State after Switching Off at the Main Switch Edition 08/2011 EN
110
The following table specifies the voltages of modules when the automatic placement system is
switched off at the main switch, but still connected to the main supply.
2
Module Voltage
Terminal panel X100
Line filter Z1
Terminals L1, L2, L3
3 x 208 VAC
3 x 230 VAC
3 x 380 VAC
3 x 400 VAC
3 x 415 VAC
Service socket X102
120 VAC
130 VAC
220 VAC
230 VAC
240 VAC
Automatic circuit breaker F1
120 VAC
130 VAC
220 VAC
230 VAC
240 VAC
Main switch Q1
Terminals L1, L2, L3
3 x 208 VAC
3 x 230 VAC
3 x 380 VAC
3 x 400 VAC
3 x 415 VAC
Main switch Q1
Terminals T1, T2, T3
0 VAC
Power supply unit
(see item 5 of fig. 2.9 - 2
)
Test socket X11
GND X12
Test socket X13_1
Test socket X13_4
GND X13_7
< 10 VDC
< 10 VDC
< 10 VDC
Computer unit (see fig. 2.11 - 3
)
Test socket + 12 VDC
Test socket - 12 VDC
Test socket + 15 VDC
Test socket -15 VDC
Test socket + 5 VDC
Test socket + 52 VDC
Test socket + 3.3 VDC
GND
0 VDC
0 VDC
0 VDC
0 VDC
0 VDC
0 VDC
0 VDC