4 Setting Up and Commissioning User Manual SIPLACE CA 4.4 Infrastructure of Installation Location Edition 08/2011 EN 260 4.4.2.2 Compressed Air Connection on the Placement Machine 4 Fig. 4.4 - 1 Compressed air line conne…

100%1 / 508
User Manual SIPLACE CA 4 Setting Up and Commissioning
Edition 08/2011 EN 4.4 Infrastructure of Installation Location
259
4.4.1.2 Vibration Thresholds
The placement machine is not susceptible to floor vibrations but the following vibration limits
should still be observed.
4
4
4.4.2 Compressed Air Supply
4.4.2.1 Checking the Compressed Air Supply
Check whether the compressed air supply complies with the prescribed machine specifications
(see table in section 3.3
, page 125).
Note: 4
The document "Network Configuration (Electricity and Compressed Air) for SMD Systems at the
Customer Site" [00191409-xx] describes measures for achieving the required specifications.
Record the compressed air characteristics at the installation location.
Parameter Values
Third-octave spectral value of the vibration speed 5 - 100 Hz
v < 250 µm/s
v
max
value on the time curve
v
max
< 1.5 mm/s
4 Setting Up and Commissioning User Manual SIPLACE CA
4.4 Infrastructure of Installation Location Edition 08/2011 EN
260
4.4.2.2 Compressed Air Connection on the Placement Machine
4
Fig. 4.4 - 1 Compressed air line connection
(1) Stop valve in the "OPEN" position
(2) Manometer for the machine component supply pressure
Target pressure: 0.5 ± 0.025 MPa, 5 ± 0.25 bar (display range 0 - 0.6 MPa, 0 - 6 bar)
(3) Manometer for the gantry distributor supply pressure
Target pressure: 0.46 ± 0.01 MPa, 4.6 ± 0.1 bar (display range 0 - 0.6 MPa, 0 - 6 bar)
(4) Manometer for the bulkcase feeder supply pressure
Target pressure: 0.25 ± 0.05 MPa, 2.5 ± 0.5 bar (display range: 0 - 0.6 MPa, 0 - 6 bar)
(5) Manometer for input pressure
Target pressure: 0.5 - 1.0 MPa, 5 - 10 bar (display range: 0 - 1.0 MPa, 0 - 10 bar)
(6) Compressed air filter
(7) Compressed air connection
(8) Hexagon socket-head screw for fixing the pneumatic unit
WARNING
NEVER detach compressed air lines while they are still pressurized. Risk of injury. 4
User Manual SIPLACE CA 4 Setting Up and Commissioning
Edition 08/2011 EN 4.4 Infrastructure of Installation Location
261
4.4.3 Compressed Air Supply on the SWS
The compressed air fed to the SWS is directly supplied via the placement machine. (See also
3.3.2
on page 125.)
4.4.4 Power Supply to the Placement Machine
4
Fig. 4.4 - 2 Position of the power supply on the placement machine
4
(1) Lock
(2) Main power switch secured to prevent switching on again
(3) Cover