User Manual SIPLACE CA 2 Operational Safety
Edition 08/2011 EN 2.11 Energy State after Switching Off at the Main Switch
103
2
Fig. 2.10 - 2 Electrical and pneumatical connection point at the SWS
2
2.11 Energy State after Switching Off at the Main Switch
CAUTION 2
Please note that each SWS module has its own main switch.
(1) Manometer for compressed air supply (2) Voltage supply
(3) Communication with SIPLACE machine (4) CAN bus
(5) Compressed air connection (modified
adapter dummy connector [03011592-01])
(6) LAN1
(7) LAN2
2
1
3
4
5
6
7
2 Operational Safety User Manual SIPLACE CA
2.11 Energy State after Switching Off at the Main Switch Edition 08/2011 EN
104
2.11.1 Main Switch on Placement Machine
2
Fig. 2.11 - 1 Position of the power supply on the machine
2
WARNING
The placement system is supplied with 3 x 208 VAC, 3 x 230 VAC, 3 x 380 VAC, 3 x 400 VAC or
3x415VAC ± 5%, 50/60Hz mains voltage. This means that some parts of the system carry po-
tentially lethal voltages - even when switched off at the main power switch. Incorrect handling of
the placement system can therefore result in death or severe injury or considerable damage to
equipment. 2
Always follow the applicable accident prevention and DIN regulations (particularly DIN EN 60
204, part 1).
The guard over the power supply unit must ONLY be opened by appropriately qualified and
trained personnel.
(1) Main switch
User Manual SIPLACE CA 2 Operational Safety
Edition 08/2011 EN 2.11 Energy State after Switching Off at the Main Switch
105
2
Fig. 2.11 - 2 Position of main power switch and service socket
(1) Main switch
(2) Service socket