00195941-03-UM SiplaceCA-EN.pdf - 第462页
7 Station Enlargements User Manual SIPLACE CA 7.3 SIPLACE High-Force Head Edition 08/2011 EN 462 7.3 SIPLACE High-Force Head [001 19734-xx]High force head for X series This item number only applie s when a new placement …

User Manual SIPLACE CA 7 Station Enlargements
Edition 08/2011 EN 7.2 Component Reject Bin Sensor
461
7.1.6 Component Reject Bin for the SIPLACE TwinHead
A component reject bin may be installed for the SIPLACE TwinHead. It is positioned next to the
fine pitch Vision module.
7
Fig. 7.1 - 30 Component reject bin for the SIPLACE TwinHead
7.2 Component Reject Bin Sensor
[00116848-xx]Query component reject bin X series/D3
The sensor for the component reject bin monitors whether the reject bin is seated correctly in its
mount.
– If the reject bin was not inserted correctly, the placement machine cannot be started.
– If the reject bin jumps out of its mount during the placement process, the machine is stopped
immediately to avoid a head crash.
Each reject bin can be monitored by a separate sensor.
NOTE 7
We recommend to install the optional component sensor for the component reject bin at a loca-
tion without SWS when a 20 segment Collect&Place head is used.

7 Station Enlargements User Manual SIPLACE CA
7.3 SIPLACE High-Force Head Edition 08/2011 EN
462
7.3 SIPLACE High-Force Head
[00119734-xx]High force head for X series
This item number only applies when a new placement machines is ordered with a High-
Force Head rather than a standard TwinHead. 7
[00119753-xx] High force upgrade kit
Use this item number if you want to replace a standard TwinHead with a High-Force Head.7
7.3.1 General
The SIPLACE high-force head is an advanced development of the standard TwinHead. It can pro-
cess the same component range and also offers the possibility of achieving set-down forces up to
30 N.
All other technical data are the same for the TwinHead and the high-force head (see section
3.8.6.3
, page 207).
All the nozzles and grippers that are used with the standard TwinHead can be used for the SI-
PLACE High-Force Head.
Programmable set-down force 2.0 N to 10 N ± 10 %
greater than 10 N up to 30 N ± 15 %

User Manual SIPLACE CA 7 Station Enlargements
Edition 08/2011 EN 7.4 Component Camera for the TwinHead, FC Camera
463
7.4 Component Camera for the TwinHead, FC Camera
7.4.1 Stationary P&P component camera (type 25) 16 x 16, digital (FC camera)
[00119718-xx]Component camera, stationary 16x16 digital, type 25
7
Fig. 7.4 - 1 Stationary P&P component camera (type 25) 16 x 16, digital (FC camera)
(1) Camera housing with integral camera and camera amplifier
(2) Glass plate - illumination and lens below
7