00195941-03-UM SiplaceCA-EN.pdf - 第283页
User Manual SIPLACE CA 4 Setting Up and Commissioning Edition 08/2011 EN 4.5 Setting Up the Placement Machine 283 4 CAUTION 4 Make sure that this half of the extension kit does not collide with the hexagonal shaft of the…

4 Setting Up and Commissioning User Manual SIPLACE CA
4.5 Setting Up the Placement Machine Edition 08/2011 EN
282
4
Fig. 4.5 - 9 Fitting the conveyor cover and the second half of the extension kit
(1) Half of the extension kit already fitted
(2) Second half of the extension kit to be fitted
(3) Transport cover
(4) Insert 3 white plastic washers on both sides
(5) Mandrel of the conveyor cover
(6) Hole
(7) Protective cover switch
Insert 3 white plastic discs (item 4 in fig. 4.5 - 9) on each of the two mandrels (item 5 in fig.
4.5 - 9
).
Insert the mandrel (item 5 in fig. 4.5 - 9) into the drilling (item 6 in fig. 4.5 - 9).
Lift the second half of the extension kit (item 2 in fig. 4.5 - 9) up to the machine frame.

User Manual SIPLACE CA 4 Setting Up and Commissioning
Edition 08/2011 EN 4.5 Setting Up the Placement Machine
283
4
CAUTION 4
Make sure that this half of the extension kit does not collide with the hexagonal shaft of the
PCB conveyor and thus bend the shaft.
Insert the mandrel (item 5 in fig. 4.5 - 9) for the conveyor cover into the drilling (item 6 in fig.
4.5 - 9
) on the second half of the extension kit.
Position the second half of the extension kit so that the assembly bracket lies on the assembly
bar (item 7 in fig. 4.5 - 8
).
Fasten this second half of the placement machine with 2 fillister head screws M6x16 and the
corresponding disc (item 3 in fig. 4.5 - 8
).
4.5.7.3 Fastening the Hexagonal Shaft Guidance
When using a single conveyor, fasten one guidance for the hexagonal shaft (item 8 in fig. 4.5
- 7) onto the extension kit, with two fillister head screws M6x16 and discs.
When using a dual conveyor, fasten two guidances for the hexagonal shaft (item 8 in fig. 4.5
- 7) onto the extension kit, with two fillister head screws M6x16 and discs.
4.5.7.4 Establishing Cable Connections - Extension Kit on the PCB Output Side
4
4
Left-hand side of the extension kit
(viewed in the direction of travel)
Connector/cable To connector/cable
EMERGENCY STOP button
Start/Stop button
X63/03020687 X63/03002526
Protective cover switch, location 3
X53/03020409 X53/03002528
Button for the component trolley docking unit,
location 3
X232/03021056 X232/03021053
Right-hand side of the extension kit
(viewed in the direction of travel)
Connector/cable To connector/cable
Start/Stop button
Switch, PCB conveyor cover
X62/03020410 X62/03002525
Protective cover switch, location 2
X52/03006476 X52/03002527
Button for the component trolley docking unit,
location 2
X222/03021056 X222/03021052

4 Setting Up and Commissioning User Manual SIPLACE CA
4.5 Setting Up the Placement Machine Edition 08/2011 EN
284
4.5.7.5 Fitting the Ground Cable for the Doors
Fasten the two ground cables for the doors (item 4 in fig. 4.5 - 8) to the machine frame as
follows:
4
Fig. 4.5 - 10 Fitting the grounding cable
4
4
4
4
4
4.5.7.6 Checking and Setting the Protective Cover Switch
Check the function of the protective cover switch (item 7 in fig. 4.5 - 9, page 282).
Adjust the protective cover switch if necessary (see Service Manual).
Hex nut M5
Spring washer M5, DIN 7980
Washer M5, DIN 125
Cable lug, annular
Contact washer