00195941-03-UM SiplaceCA-EN.pdf - 第243页

User Manual SIPLACE CA 3 Technical Data Edition 08/2011 EN 3.15 Flexible D ual PCB Conveyor 243 3.15.8 Dual Conveyor Contro l with Single Function Menu The online help contains informat ion on controlling the dual convey…

100%1 / 508
3 Technical Data User Manual SIPLACE CA
3.15 Flexible Dual PCB Conveyor Edition 08/2011 EN
242
3.15.7.1 Asynchronous Transport
Description 3
In asynchronous mode, only one PCB in a transport track is processed. At the same time, another
PCB in the second transport track is moved into the placement position. This saves the full con-
veying time of one PCB, thus considerably increasing performance, particularly for PCBs with a
short cycle time.
Function 3
Once the machine has received the job data (panel, setup), the PCBs on the feeding belts are con-
tinuously transported to the available processing belt (provided that the processing belt is free)
throughout the placement operation. The placement sequence starts as soon as a PCB has
moved onto the processing belt. The PCBs are processed one after another.
If the placement sequence is interrupted, the conveyor interface will be disabled and the PCBs
currently on the processing belts will be completed.
The conveyor interface is disabled or enabled simultaneously for both transport tracks.
3
3
3.15.7.2 Synchronous Transport
Description 3
In synchronous mode, two PCBs of the same size are moved into the placement position at the
same time. They must be processed as a common panel.
This facilitates the processing of a board upper and underside in one line. The time needed for
board transport is reduced as two boards are always transported at the same time. It also ensures
better utilization of the nozzle configuration.
Function 3
PCBs on conveyor tracks 1 and 2 are moved synchronously onto the conveyor sections (i.e. the
conveyors are controlled synchronously, but independently of one another). The components to
be placed on conveyor tracks 1 and 2 must be organized into a panel via two subpanels. (See the
SIPLACE Pro user manual).
If only one conveyor track (or center conveyor) is full when the placement sequence starts, the
subpanel on this section will be identified as “not for placement”.
Restrictions 3
If the dual conveyor is operated in synchronous mode, the ‘PCB whispering down the line’ option
is deactivated. PCB barcode operation is not supported in this mode. The "Global bad fiducial"
option cannot be used.
User Manual SIPLACE CA 3 Technical Data
Edition 08/2011 EN 3.15 Flexible Dual PCB Conveyor
243
3.15.8 Dual Conveyor Control with Single Function Menu
The online help contains information on controlling the dual conveyor and on the Single Functions
menu.
3
3
3.15.9 Automatic Width Adjustment for Dual Conveyors
When the command is received, the conveyors are set to the desired width one after another. Dif-
ferent widths are possible.
See the Online Help for detailed information about changing the conveyor track width.
3 Technical Data User Manual SIPLACE CA
3.15 Flexible Dual PCB Conveyor Edition 08/2011 EN
244