00195941-03-UM SiplaceCA-EN.pdf - 第279页
User Manual SIPLACE CA 4 Setting Up and Commissioning Edition 08/2011 EN 4.5 Setting Up the Placement Machine 279 Dismantle the cable covers (item 3 and 5 in fig. 4.5 - 7 ) from the sides (item 1 in fi g. 4. 5 - 7 ) of…

4 Setting Up and Commissioning User Manual SIPLACE CA
4.5 Setting Up the Placement Machine Edition 08/2011 EN
278
4.5.6 Fitting the Output Conveyor
4.5.6.1 Tools
– Allen keys, DIN 911, set
– Phillips screwdriver, size 1
4.5.6.2 Setting Up
4
Fig. 4.5 - 7 Output conveyor - dual conveyor
(1) Side panel, output conveyor
(2) Side panel, processing conveyor 2
(3) Cable cover 20 x 200
(4) Countersunk screw, ISO 7046, M3x6, 2x per cable cover
(5) Cable cover 20 x 310
(6) Fillister head screw DIN 912, M3x5, 1x per cable cover
(7) Fillister head screw DIN 912, M6x16, and washer, 4x per panel
(8) Hexagonal shaft guidance
(9) Hexagonal shaft (single conveyor: one, dual conveyor: two)
(10)Drive unit

User Manual SIPLACE CA 4 Setting Up and Commissioning
Edition 08/2011 EN 4.5 Setting Up the Placement Machine
279
Dismantle the cable covers (item 3 and 5 in fig. 4.5 - 7) from the sides (item 1 in fig. 4.5 - 7)
of the output conveyor.
Place the side (item 1 in fig. 4.5 - 7) carefully on the side of the processing conveyor (item 2
in fig. 4.5 - 7
).
CAUTION 4
Be careful not to cut through any of the light barrier or drive motor cables.
Fasten each side with 4 fillister head screws M6x16 and the corresponding discs (item 7 in
fig. 4.5 - 7
).
Connect the power cable to the light barriers and drive motors.
Fasten the cable covers (item 3 and 5 in fig. 4.5 - 7).
Insert the hexagonal shaft (item 9 in fig. 4.5 - 7) into the drive unit (item 10 in fig. 4.5 - 7).
Make sure that the hexagonal shaft guidance (item 8 in fig. 4.5 - 7) is always pointing towards
the conveyor side on which the drive unit (item 10 in fig. 4.5 - 7
) is fixed.
4.5.7 Install Extension Kit to the PCB Output Side
4.5.7.1 Tools
– Allen keys, DIN 911, set
– Machine key

4 Setting Up and Commissioning User Manual SIPLACE CA
4.5 Setting Up the Placement Machine Edition 08/2011 EN
280
4.5.7.2 Setting Up
4
Fig. 4.5 - 8 Install extension kit to the PCB output side
(1) Extension kit
(2) Door
(3) Fillister head screw DIN 912, M6x16 and washer
(4) Grounding connection
(5) Transport cover
(6) Side plate, dismantled
(7) Insert rail
(8) Axis unit CA4 gantries 2 and 3 (CA4)
Remove both side plates (item 6 in fig. 4.5 - 8).