OK button: Moves the head to the component di sposal position. E506401 “ Cannot return component of %s. Tr ash component? ” “ %s 的组件不能归还, | 是否废弃它? ” [Cause] This message appears when star ting a production if a compon en…

100%1 / 464
E506201 You need to delete the file if you do not resume the production from the last illegally suspended
position. | [Circuit No. : %d Step No. : %d]| Would you like to delete the file?
在生产基板中,如果不想执行前一次异常退出时|[电路号: %d 步骤号: %d]|的继续生产,
有必要删除它,|是否删除?
[Cause]
This message appears if the production program is a resumable production when starting a
production.
(Other than 2030)
|Resumptive production starting position of each station.
[Treatment]
Yes : Starts the production from the placement point which got illegal abortion last time.
No : Will not resume the production but start a normal production that is set in the Production
Condition.
E506202 Would you like to resume the production? The last suspended position [Circuit No. : %d Step No. :
%d]
[Cause]
This message appears if the production program is a resumable production when starting a
production.
(Other than 2030)
|Resumptive production starting position of each station.
[Treatment]
Yes : Starts the production from the placement point which got illegal abortion last time.
No : Will not resume the production but start a normal production that is set in the Production
Condition.
E506300 Is the component supply reset?
是否要补满组件?
[Cause]
This message appears when 'replenishment button' on the Pause screen is pressed.
[Treatment]
Yes : Replenishes components.
No : Will not replenish components.
E506400 The %s component is a protective component. Please remove the component
%s 的组件是保护组件,请取下组件
[Cause]
This message appears before disposing the component if a protective component is being picked by a
head when starting a production.
[Treatment]
OK button: Moves the head to the component disposal position.
E506401 Cannot return component of %s. Trash component?
%s 的组件不能归还,|是否废弃它?
[Cause]
This message appears when starting a production if a component is being picked by a head, the
component is not a protective component, and the component disposal is executed for the component
that is UN-returnable.
[Treatment]
Yes : Disposes the component.
No : Resumes the production without disposing the component.
E506500 More than one component are selected. Would you like to try execute Verification inspection for
the first component listed?
多数组件被选择,|是否要显示第一组件数据的编辑对话框?
[Cause]
This message appears if several components are selected to be verified when executing the
Verification inspection for the retry list.
[Treatment]
Yes : Executes the Verification inspection for the first component listed.
No : Will not executes the Verification inspection.
Q506600 Air has not been supplied.|Would you like to begin production though the PWB may become
incomplete?
气压被下降,|可能发生贴片遗漏现象,是否开始生产?
E507602 This program is not available for measuring general placement offset.”
不是贴片综合偏差生产用的生产程序。
E507606 Auto.Select exists in the Place data. |Production can not be executed.”
贴片数据内存在自动选择,|不能执行生产。
Q506700 There is no component that ran out.|Would you like to begin production?
"存在组件短缺的组件,|是否开始生产?"
Q506701 Fail in the measurement of the height of component.|Would you like to begin production?
"测量组件高度失败,|是否开始生产?"
Q506702 Aborted in the measurement of the height of component.|Would you like to begin production?
"测量组件高度被中断,|是否开始生产?"
Q506711 Failed in verification of component.|Would you like to begin production?
" 数值检查失败,| 是否开始生产? "
Q506712 Aborted in verification of component.|Would you like to begin production?
" 中断数值检查,| 是否开始生产?"
Q506721 Failed in SOT direction of component.|Would you like to begin production?
"SOT 方向检查失败,|是否开始生产?"
Q506722 Aborted in SOT direction of component.|Would you like to begin production?
"SOT 方向检查被中断,|是否开始生产?"
Q506800 The total number of placements( %d) differs form the number( %d) set in the Production
Condition.|Would you like to begin production?
"总贴片数( %d)与生产条件上设置的末行数( %d)不同,|是否进行生产?"
Q506801 The restart production is set only as for a %s. A %s does not do the restart production.|Would you
like to begin production?
"只有%s 被设置成重新开始生产。%s 不能重新开始生产,|是否进行生产?"
Q506802 Only the point equipped with the circuit setting the restart position is set. |When neither is set, the
restart production is not done.|Would you like to begin production?
"电路或贴片点中,只有一项设置了重新开始位置,|如果两个项不都设置,就不能进行重
新生产。|是否开始生产?"
Q506803 The position where it is restarted that it is not in the prod. station is set.|If the position where the
prod. station side is restarted is not input, the restart production is not done.|Would you like to begin
production?
"设置了生产运行站台上不存在的重新开始位置,|如果不输入生产运行站台的重新开始位
置,就不能进行重新生产。|是否开始进行生产?"
Q506804 The specification of the production execution station (%s) and the Trace execution station is
different.|You do not trace when starting as it is.Is production executed?
"生产运行站台(%s)与跟踪运行站台(%s)不同,|这种设置不能执行跟踪,是否进行生产?"
Q506805 The production execution station (%s) is a single station and the station specification of the trace
(%s) is both station.|Is production executed though the station where the trace is not executed is
generated?
"生产运行站台是一个站台(%s),但跟踪站台指定了两个站台。|即使站台不执行跟踪,也进
行生产?"
Q506900 %s has been set on the pick position.|Do you want to change the trays?