E610213 “ The error not forecast occurred ” “ 发生未知错误。 ” [Cause] An undefined error occurred. [Treatment] Please turn off the power supply of your machine and reboot it. E610214 “ X Driver alarm occurred ” “ 发生 X 驱动警报。 ” …
“发生+Y 界限。”
[Cause]
The head is on the +limit sensor (rear side) which is on the Y axis.
[Treatment]
Please get the head off the limit sensor, and then perform the Home returning.
E610210 “Y limit occurred”
“发生-Y 界限。”
[Cause]
The head is on the -limit sensor (front side) which is on the Y axis.
[Treatment]
Please get the head off the limit sensor, and then perform the Home returning.
E610211 “YCNV limit occurred”
“发生+YCNV 界限。”
[Cause]
The movable station (right side) of the PWB conveyor is on the +limit sensor (rear side).
[Treatment]
1. If the right movable station is inward of the machine by 5mm compared with the left fixed station.
If your machine installs a changer table on it, please take it off your machine. Stick your hand from
the front side of the machine and reach beneath the backup table. Turn the coupling part that holds a
ball screw and a motor axis that drive the movable station in order to adjust the position of the
movable station to the position of the left station.
2. If the position of the right movable station is almost on the same position as the left station.
The limit sensor of the movable station is broken. It could be that the sensor itself is broken or that a
connector came off the sensor. Please take the backup table off the machine and examine the sensor.
E610212 “YCNV limit occurred”
“发生-YCNV 界限。”
[Cause]
The movable station (right side) of the PWB conveyor is on the -limit sensor (front side).
[Treatment]
1. If the right movable station is outward of the machine by 5mm compared with the left fixed station.
If your machine installs a changer table on it, please take it off your machine. Stick your hand from
the front side of the machine and reach beneath the backup table. Turn the coupling part that holds a
ball screw and a motor axis that drive the movable station in order to adjust the position of the
movable station to the position of the left station.
2. If the position of the right movable station is almost on the same position as the left station.
The limit sensor of the movable station is broken. It could be that the sensor itself is broken or that a
connector came off the sensor. Please take the backup table off the machine and examine the sensor.
E610213 “The error not forecast occurred”
“发生未知错误。”
[Cause]
An undefined error occurred.
[Treatment]
Please turn off the power supply of your machine and reboot it.
E610214 “X Driver alarm occurred”
“发生 X 驱动警报。”
[Cause]
An abnormal matter happened to the servo driver of the X axis.
[Treatment]
Please turn off the power supply of your machine and reboot it. If the error occurs even after the
reboot, please see if the cables are connected properly. If the error still occurs even when the cables
are connected properly, you need to replace the servo driver of X axis with a new one.
E610215 “XR Driver alarm occurred”
“发生 XR 驱动警报。”
[Cause]
An abnormal matter happened to the servo driver of the XR axis.
[Treatment]
Please turn off the power supply of your machine and reboot it. If the error occurs even after the
reboot, please see if the cables are connected properly. If the error still occurs even when the cables
are connected properly, you need to replace the servo driver of XR axis with a new one.
E610216 “Y Driver alarm occurred”
“发生 Y 驱动警报。”
[Cause]
An abnormal matter happened to the servo driver of the Y axis.
[Treatment]
Please turn off the power supply of your machine and reboot it. If the error occurs even after the
reboot, please see if the cables are connected properly. If the error still occurs even when the cables
are connected properly, you need to replace the servo driver of Y axis with a new one.
E610217 “XR Driver alarm occurred”
“发生 YR 驱动警报。”
[Cause]
An abnormal matter happened to the servo driver of the YR axis.
[Treatment]
Please turn off the power supply of your machine and reboot it. If the error occurs even after the
reboot, please see if the cables are connected properly. If the error still occurs even when the cables
are connected properly, you need to replace the servo driver of YR axis with a new one.
E610218 “YCNV Driver alarm occurred”
“发生 YCNV 驱动警报。”
[Cause]
An abnormal matter happened to the servo driver on the right movable station of the PWB conveyor.
[Treatment]
Please turn off the power supply of your machine. If the error occurs even after the reboot, please see
if the cables are connected properly. If the error still occurs even when the cables are connected
properly, you need to replace the servo driver on the right movable station of the PWB conveyor with
a new one.
E610219 “X SLOW occurred”
“发生 X 轴低速。”
[Cause]
Left and right heads got too close and the sensor got ON to prevent the left and right heads from
clashing with each other. Therefore, the axis was forced to stop travel slow.
[Treatment]
Please turn off the power supply of your machine and reboot it. If the error occurs even after the
reboot, the following causes can be possible.
‧A light reflective sensor detects if the left and right heads get too close with each other or not.
Please make sure that there is nothing that the sensor reacts to.
‧The sensitivity of the sensor is too high. Please adjust the sensitivity control volume on the sensor
to make it that the sensor gets on when the distance between the heads gets less than 230mm.
‧The sensor is broken. It could be that a sensor cable came off the connector, that a cable got cut off,
or that the sensor itself is broken.
‧The MCM board in the sensor is broken.
E610220 “X STOP occurred”
“发生 X 轴停止。”
[Cause]
Left and right heads got too close and the sensor got ON to prevent the left and right heads from
clashing with each other. Therefore, the axis was forced to stop traveling.
[Treatment]
Please turn off the power supply of your machine and reboot it. If the error occurs even after the
reboot, the following causes can be possible.
‧The sensor is broken. Please examine if the sensor cable came off the connector, the cable got cut
off, or the sensor itself is broken.
‧The MCM board in the sensor is broken.