" 在 %dth 程序中的图像 数据不完全。 " E6427 “ Specified number supplied in % dth program exceeds resource. “ " 在 % d t h 程序供给指定数量超过资源数。 " E6428 “ Assigned placement data in %dth program exi st in multiple stati on…
Complete the mounting data.
E6404 Component data is not completed.
"组件数据不完全。"
[Cause]
The part data where the mounting position is allocated is incomplete.
[Deal]
Complete the part data.
E6405 Pick data are incomplete.
"吸取数据不完全。"
[Cause]
The pick data is incomplete.
[Deal]
Complete the pick data.
E6406 “Vision data is not completed. “
"图像数据不完全。"
E6407 “Specified number supplied exceeds resource. “
"提供的特殊数字超过资源数。"
E6408 “Assigned placement data exist in plural number of stations. “
"指定贴片数据存在于复数位置。"
E6409 “Assigned pick data exist in multiple stations. “
"指定挑选数据存在于多个位置。"
E6420 “Component in %dth program is overlapped with permanent component. “
"在%dth 程序中的组件被永久组件覆盖 "
E6422 “PWB data in %dth program is not completed. “
"在%dth 程序的基板 B 数据不完全。"
E6423 “Placement data in %dth program is not completed. “
"在%dth 程序的贴片数据不完全。"
E6424
“Component data in %dth program is not completed. “
"在%dth 程序的组件数据不完全。"
E6425 “Pick data in %dth program is not completed. “
"在%dth 程序中的吸取数据不完全。"
E6426 “Vision data in %dth program is not completed. “
"在%dth 程序中的图像数据不完全。"
E6427 “Specified number supplied in %dth program exceeds resource. “
"在 %dth程序供给指定数量超过资源数。"
E6428 “Assigned placement data in %dth program exist in multiple stations. “
"在%dth 程序中的指定贴片数据存在于多个位置。"
E6429 “Assigned pick data in %dth program exist in multiple stations. “
"在%dth 程序中的指定挑选数据存在于多个位置。"
E6440 The number of placemently resident nozzles exceeds the resource.
"固定吸嘴数量超过资源量。"
[Cause]
The number of the placement nozzles has exceeded the available number of resources.
[Deal]
Increase the number of nozzles specified in the MSL setup resource.
E6441 “Number of permanent feeders exceeds resource. “
"固定进料器数量超过资源量。"
E6442 %s over resource.
[Cause]
The number of feeders has exceeded the available number of resources.
[Deal]
Increase the number of feeders specified in the MSL setup resource.
E6450 “Permanent data cannot be set. “
"永久数据不能被设置。"
E6451 “Protected data cannot be set. “
"保护数据不能被设置。"
E6452 “
Production control data allocation failed. “
"产品控制数据分配失败。"
E6453 “Production condition data allocation failed. “
"产品情况数据分配失败。"
E6454 “Global fiducial data allocation failed. “
"球型基准数据分配失败。"
E6455 “Permanently resident nozzle allocation failed. “
"永久的常驻的吸嘴分配失败。"
E6456 “Permanently resident feeder allocation failed. “
"永久的常驻的进料器分配失败。"
E6457 “Already assigned pick data allocation failed. “
"已经指定的挑选数据分配失败。"
E6458 “A station to which pick data have already been assigned is excluded as an object of partition. “
"已经被指定的选择数据位置作为区分目标被排除."
E6459 “Already assigned placement data allocation failed. “
"已经指定的贴片数据分配失败。"
E6460 The head corresponding to the already assigned placement data cannot be used.
"已分配给位置的相应的头没有使用。"
[Cause]
Indicates that the station specified for the feeder in mounting and absorption data is different from the
allocated station.
[Deal]
Use the automatic selection to specify the station for the mounting data and absorption data for
optimization.
E6461 “The already assigned placement data MTC cannot be used. “
"不能使用已指定贴片数据 MTC。"
E6462 Some pick data are designated in non-distrubutable station.
"不能设置已指定贴片数据吸嘴。"
[Cause]
Indicates that the data for the absorbing point specification has been already used for the occupation
data.
[Deal]
Use the automatic selection to specify the station for the mounting data and absorption data for
optimization.
E6463 Some placement data are designated in non-distributable station.
"已指定的贴片数据贴片层相互矛盾。"
[Cause]
Indicates that the data for mounting specification is allocated for more than one station.
[Deal]
Use the automatic selection to specify the station for the mounting data and absorption data for
optimization.