JUKI贴片机错误代码.pdf - 第433页

a part data inspection item. [Deal] Add a 740,760,2020 or 2040 st ation on the line during t he MSL set E3841 Veri fy function is not available on this station. [Cause] Indicates that the specifie d station is none of a …

100%1 / 464
[Cause]
Indicates that none of 720, 730, 740, 750,760,2010,2020 and 2040 stations is set on the line, but the
part data specifies the tray (MTC) for the package style on the line.
[Deal]
Add any of a 720, 730, 740, 750,760,2010,2020 and 2040 station on the line during the MSL setup.
E3836 MTC is assigned to the station which cannot handle it.
"MTC 被分配给的位置不能处理."
[Cause]
Indicates that the specified station is none of 720, 730, 740, 750,760,2010,2020 and 2040 stations, or
it is disabled in the unit status of the MSL setup.
[Deal]
Make sure that the specified station is the one capable of using the MTC, or is not disabled in the
unit status during the MSL setup, and restart the process.
E3837 Standard VCS is not available on this station.
[Cause]
Indicates that the specified station is none 720, 740,760,2020 and 2040 stations, or it is disabled in the
unit status of the MSL setup.
[Deal]
Make sure that the specified station is the one capable of using the MTC, or is not disabled in the
unit status during the standard VCS setup, and restart the process.
E3838 No station in the line can use standard VCS.
[Cause]
Indicates that none of a 720, 740,760,2020 and 2040 stations is set on the line, despite the vision part
is enabled.
[Deal]
Add one of a 720, 740,760,2020 and 2040 stations on the line during the MSL setup.
E3839 Coplanarity function is not available on this station.
[Cause]
Indicates that the specified station is not a 740,760,2020 or 2040 station, or the coplanarity is disabled
in the unit status during the MSL setup.
[Deal]
Make sure that the specified station is a 740,760,2020 or 2040 station, or the coplanarity is enabled
in the unit status during the MSL setup.
E3840 No station in the line can use coplanarity function.
[Cause]
Indicates that there is no 740,760,2020 or 2040 station on the line despite the coplanarity is enabled as
a part data inspection item.
[Deal]
Add a 740,760,2020 or 2040 station on the line during the MSL set
E3841 Verify function is not available on this station.
[Cause]
Indicates that the specified station is none of a 730, 740, 750 and 760 stations, or the verification is
disabled in the unit status during the MSL setup.
[Deal]
Make sure that the specified station is one of a 730, 740, 750 and 760 stations, or the verification is
enabled in the unit status during the MSL setup.
E3842 No station in the line can use verify function.
[Cause]
Indicates that the line has none of a 730, 740, 750,760 and 2000 series stations, despite the
verification is enabled in the unit status during the MSL setup.
[Deal]
Add one of a 730, 740, 750,760 and 2000 series stations on the line during the MSL setup.
E3843 No station in the line has laser centering.
[Cause]
Indicates that the line has none of 730, 740, 750,760 and 2000 series stations, despite the laser
centering is enabled in the part data.
[Deal]
Add one of 730, 740, 750,760, 2000 series and stations on the line during the MSL setup.
E3844 No station in the line has mechanical centering.
[Cause]
Indicates that the line has neither of a 710 nor 720 station on it, despite the mechanical centering is
enabled in the part data.
[Deal]
Add either of a 710 or 720 station on the line during the MSL setup.
E3845 No station in the line can use nozzle No.0.
[Cause]
Indicates that the line has neither of a 710 nor 720 station on it, despite nozzle 0 is enabled in the part
data.
[Deal]
Add either of a 710 or 720 station on the line during the MSL setup.
E3846 No station in the line can use nozzle No. 1 to 4.
[Cause]
Indicates that the line has neither of a 710 nor 720 station on it, despite nozzles 1 to 4 are enabled in
the part data.
[Deal]
Add either of a 710 or 720 station on the line during the MSL setup.
E3847 No station in the line can use nozzle No. 10 to 19.
[Cause]
Indicates that the line has neither of a 710 nor 720 station on it, despite nozzles 10 to 19 are enabled
in the part data.
[Deal]
Add either of a 710 or 720 station on the line during the MSL setup.
E3848 No station in the line can use nozzle No. 100 to 149.
[Cause]
Indicates that the line has none of 730, 740, 750 and 760 stations on it, despite nozzles 100 to 149
are enabled in the part data.
[Deal]
Add one of 730, 740, 750 and stations on the line during the MSL setup.
E3849 No station in the line can use nozzle No. 200 to 249.
[Cause]
Indicates that the line has a 740 and 760 stations on it, despite nozzles 200 to 249 are enabled in the
part data.
[Deal]
Add a 740 and/or 760 stations on the line during the MSL setup.
E3850 No station in the line can accept this nozzle.
[Cause]
The nozzle specified for the line is not located at the specified station.
[Deal]
Allocate the specified nozzle to another station or add the station you want to specify to the line with
the MSL Setup program.
E3851 No station in the line can accept components which height is more than 10mm.
[Cause]
Indicates that the line has none of 730, 740, 750,760,2010,2020 and 2040 stations.
[Deal]
Add one of 730, 740, 750,760,2010,2020 and 2040 stations on the line during the MSL setup.
E3852 No station in the line can accept components which width is more than 20mm.