JUKI贴片机错误代码.pdf - 第352页

Ref. pin sensor is broken. It could be that the wiring came off the connect or, that a contact pin in the connector part is broken, that wiring got cut off, or that sens or itself is b roken. Please ex amine the wiring a…

100%1 / 464
1) Please turn off the power supply of your machine and reboot it.
2) If the treatment1 does not work, please see if the wiring and connectors in the XMP board are
properly connected.
3) If the treatment2 does not work, you need to change the XMP board to a new one.
E650295 Clamp error : Something is wrong with the backup motor movement on the center station on the
Exit side. The process is forcibly terminated. Please remove on the conveying route
基板固定错误 :|出口侧中心缓冲区,支撑台马达运转异常。
[Cause]
The backup plate on the center station on the Exit side did not get to the aimed clamp height. As a
cause, there is a possibility that the firmware on the XMP board has a problem.
[Treatment]
The firmware on the XMP board to make the backup plate up and down is not under the control
mode.
1) Please turn off the power supply of your machine and reboot it.
2) If the treatment1 does not work, please see if the wiring and connectors in the XMP board are
properly connected.
3) If the treatment2 does not work, you need to change the XMP board to a new one.
E650296 Clamp error : Hole reference process at the center station on the Exit side finished illegally. The
process is forcibly terminated. Please remove on the conveying route
基板固定错误 :|出口侧中心缓冲区,孔基准动作异常。
[Cause]
The backup plate got to the aimed clamp height but the Ref. pin sensor did not get ON. This error is
likely to occur when the Ref. pin did not get in the positioning hole correctly.
[Treatment]
1 The Ref. pin on the center station on the Exit side is not in the positioning hole correctly.
Please set the positions of the Ref. pin and the follower pin on the center station on the Exit side
correctly to the position of the Ref. hole. If you want to position PWBs with Outer shape Ref., please
make sure that Outer shape Ref.”
is enabled in the PWB data in the Program Editor.
2 The Ref. pin on the center station on the Exit side is in the positioning hole correctly.
Select [Manual Control] from the menu bar, and then select [Control(C)] [Conveyor(C)] [Independent
Control of Conveyor(I)] to see the status of Ref. pin sensor in the 'Status' frame. Select 'backup plate'
in the 'Control' item' on this screen to make the backup plate up and down. At this point, set the
Destination coordinates(up)(M) to -1.6mm.
1) When the Ref. pin sensor in the 'Status' frame does not get ON/OFF, there is a possibility that the
sensor is not installed properly. Please re-install the sensor to where it gets ON/OFF correctly.
2) When the Ref. pin sensor in the 'Status' frame does not get ON/OFF, there is a possibility that the
Ref. pin sensor is broken. It could be that the wiring came off the connector, that a contact pin in the
connector part is broken, that wiring got cut off, or that sensor itself is broken. Please examine the
wiring and the connector. If any of them are broken, you need to replace them with new ones.
3) When the Ref. pin sensor in the 'Status' frame does get ON/OFF, there is a possibility that the
signal line of the Ref. pin sensor is broken. It could be that the wiring came off the connector part,
that a contact pin in the connector part is broken, or that signal line got cut off. Please examine the
wiring and the connector. There also is another possibility that the screw that holds the encoder and
the encoder axis together is loose. Please make sure that the screw is tightened up enough.
4) If the treatments mentioned above do not work, a PCB is broken or the wiring between the PCBs is
bad.
E650297 Clamp Error :| Backup plate stopper of the center buffer | on the Exit side lock up illegally.”
基板固定错误 :|出口侧中心缓冲区,支撑台制动器固定错误。
E650298 Clamp Error :| Backup plate stopper of the center buffer | on the Exit side release illegally.”
基板固定错误 :|出口侧中心缓冲区,支撑台制动器释放错误。
W650309 Idle PWB Conveying Error : PWB is detected on the conveying route. Please remove it
传送基板(通过)错误 :|传送轨道上发现基板。
[Cause]
In the Idle PWB Conveying process, several buffers on the conveying route detected unexpected
PWBs on the conveying route.
[Treatment]
Please remove the PWBs on the conveyor.
W650311 Idle PWB Conveying Error : A PWB is detected on the center station. Please remove it
传送基板(通过)错误 :|中心缓冲区发现基板。
[Cause]
In the Idle PWB Conveying process, unexpected PWBs were detected on the center station on the
conveyor.
[Treatment]
Please remove the PWBs on the center station.
W650312 Idle PWB Conveying Error : A PWB is detected on the center station on the Entrance side. Please
remove it
传送基板(通过)错误 :|入口侧中心缓冲区发现基板。
[Cause]
In the KE2030 Idle PWB Conveying process, unexpected PWBs were detected on the center station
on the Entrance side on the conveyor.
[Treatment]
Please remove the PWBs on the center station on the Entrance side.
W650313 Idle PWB Conveying Error: A PWB is detected on the center station on the Exit side. Please
remove it
传送基板(通过)错误 :|出口侧中心缓冲区发现基板。
[Cause]
In the KE2030 Idle PWB Conveying process, unexpected PWBs were detected on the center station
on the Exit side on the conveyor.
[Treatment]
Please remove the PWBs on the center station on the Exit side.
W650314 Idle PWB Conveying Error : A PWB is detected on the OUT buffer. Please remove it
传送基板(通过)错误 :|出口缓冲区发现基板。
[Cause]
In the Idle PWB Conveying process, unexpected PWBs were detected on the OUT buffer conveyor.
[Treatment]
Please remove the PWBs on the OUT buffer on the conveyor.
W650319 Idle PWB Conveying Error : In operation of Idle PWB conveying
传送基板(通过)错误 :|正在运行传送基板(通过)
[Cause]
A new request of PWB conveying was issued before a previous request of PWB conveying got
complete (Program error).
[Treatment]
Please see the error message, and remove all the PWBs on the conveyor. Then try the request again.
E650321 Idle PWB Conveying Error : Illegal input buffer motor movement. The process is forcibly
terminated. Please remove on the conveying route
传送基板(通过)错误 :|入口缓冲区马达运转异常。
[Cause]
Since IN sensor detected a PWB coming in, the belt of the INPUT buffer got started to drive and the
PWB was taken in to the INPUT buffer. However, the IN sensor did not get OFF after a certain
amount of time has passed. Usually, this error occurs when a PWB can not go through the INPUT
buffer for some reason.
[Treatment]
1 If the PWB was on the position where it is detected by IN sensor when the error occurred.
The PWB can not move for it got caught on the conveyor for some reason.
1) The PWB can not go through smoothly since the conveyor is not connecting well to the machine in
the upper part of the line. Please re-adjust the connection.
2) The conveyor width is not matching the PWB width. Please re-adjust the conveyor width.
3) The PWB you are trying to convey does not match the specifications of your machine. The
following cases do not match your machine.