JUKI贴片机错误代码.pdf - 第373页
with each other. The Component Verification is broken. [Treatment] ‧If the error occurs even after a re-try, please turn off the p ower supply and re-boot your machine. ‧If the error occurs even after the re-boot, there …
‧Please set the measurement mode to the Resistance measurement mode and try again.
E690010 “The measurement is impossible since measurement mode is not set to Condenser measurement. |
Please switch to the Condenser measurement mode then try again”
“因为不是测定电容模式,不能测定电容。|请切换到测定电容模式后执行。”
[Cause]
In order to measure condenser capacity, the measurement mode has to be the Condenser measurement
mode.
‧Measurement mode is not set to the Condenser measurement mode.
[Treatment]
‧Please set the measurement mode to the Condenser measurement mode and try again.
E690011 “The measurement is impossible since measurement mode is not set to Diode measurement. | Please
switch to the Diode measurement mode then try again”
“因为不是测定电流方向模式,不能测定电流方向。|请切换到测定电流方向模式后执行。”
[Cause]
In order to measure diode polarity, the measurement mode has to be the Diode measurement mode.
‧Measurement mode is not set to the Diode measurement mode.
[Treatment]
‧Please set the measurement mode to the Diode measurement mode and try again
E690012 “The measurement is impossible since the gotten measurement mode is set to Resistance
measurement”
“因为采取的模式不是测定电阻模式,所以不能测定电阻。”
[Cause]
The measurement mode gotten from the tester is not the Resistance measurement.
The specified measurement mode and the measurement mode gotten from the tester are clashing
with each other.
‧The Component Verification is broken.
[Treatment]
‧If the error occurs even after a re-try, please turn off the power supply and re-boot your machine.
‧If the error occurs even after the re-boot, there is a possibility that the Component Verification
unit is broken. Please contact our technical service dept. for information.
E690013 “The measurement is impossible since the gotten measurement mode is set to Condenser
measurement”
“因为采取的模式不是测定电容模式,所以不能测定电容。”
[Cause]
The measurement mode gotten from the tester is not the Condenser measurement.
The specified measurement mode and the measurement mode gotten from the tester are clashing
with each other.
The Component Verification is broken.
[Treatment]
‧If the error occurs even after a re-try, please turn off the power supply and re-boot your machine.
‧If the error occurs even after the re-boot, there is a possibility that the Component Verification
unit is broken. Please contact our technical service dept. for information.
E690014 “The measurement is impossible since the gotten measurement mode is set to Diode measurement”
“因为采取的模式不是测定电流方向模式,所以不能测定电流方向。”
[Cause]
The measurement mode gotten from the tester is not the Diode measurement.
The specified measurement mode and the measurement mode gotten from the tester are clashing
with each other.
The Component Verification is broken.
[Treatment]
‧If the error occurs even after a re-try, please turn off the power supply and re-boot your machine.
‧If the error occurs even after the re-boot, there is a possibility that the Component Verification
unit is broken. Please contact our technical service dept. for information.
E690015 “The resistance when zero-adjusting is abnormal. | Please check if probe short-circuits or not”
“零位电阻有些异常。|请检查一下探针是否短路。”
[Cause]
The resistance that was gotten from the tester when adjusting the resistance is irregular.
‧The probe does not short-circuit.
‧An obstruction that has resistance is caught in the probe.
‧The Component Verification is broken.
[Treatment]
‧Please check and see if the probe short-circuits.
‧If the error occurs when the probe does not have any problems, please turn off the power supply
and re-boot your machine.
‧If the error occurs even after the re-boot, there is a possibility that the Component Verification
unit is broken. Please contact our technical service dept. for information.
E690016 “A time-out occurred while reading resistance in”
“读取电阻超时。”
[Cause]
The tester does not start outputting data when starting to measure the resistance.
‧Component Verification is broken.
[Treatment]
‧Please turn off the power supply and re-boot your machine.
‧If the error occurs even after the re-boot, there is a possibility that the Component Verification
unit is broken. Please contact our technical service dept. for information.
E690017 “A time-out occurred while reading volume in”
“读取电容超时。”
[Cause]
The tester does not start outputting data when starting to measure the condenser capacity.
‧Component Verification is broken.
[Treatment]
‧Please turn off the power supply and re-boot your machine.
‧If the error occurs even after the re-boot, there is a possibility that the Component Verification
unit is broken. Please contact our technical service dept. for information.
E690018 “A time-out occurred while reading voltage in”
“读取电压超时。”
[Cause]
The tester does not start outputting data when starting to measure the voltage.
‧Component Verification is broken.
[Treatment]
‧Please turn off the power supply and re-boot your machine.
‧If the error occurs even after the re-boot, there is a possibility that the Component Verification
unit is broken. Please contact our technical service dept. for information.
E690019 “The measured resistance does not get stable. | Please check the probe status”
“读取的电阻不稳定。|请检查探针状态。”
[Cause]
The resistance gotten from the tester does not get stable.
‧The object(component) of the measurement is not contacting the probe well.
‧Component Verification is broken.
[Treatment]
‧Please check and see if the object is contacting the probe well. If not, please adjust the position of
the object to contact the probe properly.
‧If the error occurs when the contact is good, there is a possibility that the Component Verification
unit is broken. Please contact our technical service dept. for information.
E690020 “The measured volume does not get stable. | Please check the probe status”
“读取的电容不稳定。|请检查探针状态。”
[Cause]
The condenser capacity gotten from the tester does not get stable.
‧The object(component) of the measurement is not contacting the probe well.