JUKI贴片机错误代码.pdf - 第58页

Q291502 “ The BOC alignment is ex ecuted. P lease confirm safety. | Please push 'No' when discontinui ng. 'Yes' when continuing ” “ 执行 BOC 校 准,请注意安全。 | 执行,请按 [ 是 ] ﹔停 止,请按 [ 否 ] 。 ” [Cause] You are as…

100%1 / 464
E291029 MTC is not power on.”
MTC 电源未打开。
E291030 MTC is not online.”
没有连 MTC
E291031 MTC initialize not done.”
MTC 未初始化。
E291032 MTC is in the supply state.”
MTC 处于补充状态。
E291033 MTC conveyor initialize not done.”
MTC 传送没有进行初始化。
E291034 MTC Emergency Switch is Pressed.”
MTC 处于紧急停止状态。
E291035 The PWB data is not set.”
未输入基板数据。
E291036 The Coplanarity is set in unused by the setup.
在设置中,共面检测器没有被选用
E291037 The BAD mark data is not set.| Operation is aborted.”
未设置坏板标记数据。|停止执行。
E291038 The BAD mark sensor is set in unused by the setup.
在设置中,坏板标记传感器没有被选用。
Q291500 The BOC mark recognition error. | Please push 'No' when discontinuing. 'Yes' when continuing
识别 BOC 标记失败。|继续,请按[]﹔停止,请按[]
[Cause]
The BOC mark(s) could not be recognized by VCS.
[Treatment]
There is a possibility that the BOC mark(s) could not be taught to the machine properly.
Q291501 Operation interruption. | Please push 'No' when discontinuing. 'Yes' when continuing
被用户中断。|继续,请按[]﹔停止,请按[]
[Cause]
The operation was aborted since STOP button was pressed.
[Treatment]
If you want continue the operation, press 'Yes'. If not, press 'No'.
Q291502 The BOC alignment is executed. Please confirm safety. | Please push 'No' when discontinuing. 'Yes'
when continuing
执行 BOC 准,请注意安全。|执行,请按[]﹔停止,请按[]
[Cause]
You are asked if to perform the safety check since the operation takes axis traveling.
[Treatment]
If you want to continue the operation, press 'yes'. If not, press 'No'.
Q291503 The BOC alignment is executed. Please confirm safety. | Please push 'No' when discontinuing. 'Yes'
when continuing
执行 BOC 准,请注意安全。|执行,请按[]﹔停止,请按[]
[Cause]
You are asked if to perform the safety check since the operation takes axis traveling.
[Treatment]
If you want to continue the operation, press 'yes'. If not, press 'No'.
Q291504 The BOC alignment is executed. Please confirm safety. | Please push 'No' when discontinuing. 'Yes'
when continuing
执行 BOC 准,请注意安全。|执行,请按[]﹔停止,请按[]
[Cause]
You are asked if to perform the safety check since the operation takes axis traveling.
[Treatment]
If you want to continue the operation, press 'yes'. If not, press 'No'.
Q291505 Unit is moved to escape point. Please confirm safety. | Please push 'No' when discontinuing. 'Yes'
when continuing
轴往等待位置移动,请注意安全。|行,请按[]﹔停止,请按[]
[Cause]
You are asked if to perform the safety check since the operation takes axis traveling.
[Treatment]
If you want to continue the operation, press 'yes'. If not, press 'No'.
Q291506 Conveyor width is moved. Please remove handknob and PWB from conveyor. | Please push 'No'
when discontinuing. 'Yes' when continuing
移动基板幅宽,请取下基板和摇把|执行,请按[]﹔停止,请按[]
[Cause]
You are asked if to perform the safety check by removing PWBs and a handknob from the conveyor
since the conveyor width is adjusted.
[Treatment]
If you want to continue the operation, press 'yes'. If not, press 'No'.
Q291507 The origin point return of automatic conveyor width adjustment is non-completion. Continue
anyway? | Please push 'No' when discontinue. 'Yes' when continuing
没有结束调整基版宽度的返回原点。是否执行返回原点?|执行前,请取下基板和摇把。
|执行,请按[]﹔停止,请按[]
[Cause]
You are asked if to perform the Home returning of the Auto. PWB Width Alignment Control since its
Home returning has not been complete yet.
[Treatment]
If you want to continue the operation, press 'yes'. If not, press 'No'.
Q291508 MTC Conveyor width is moved,too? | Please push 'No' when discontinue 'Yes' when continuing.”
是否也移动 MTC 装置的基板幅宽?|执行,请[]﹔停止,请按[]
I291509 Please set online for MTC.”
请联 MTC
Q291510 Conveyor width is moved. Does it move, although the vacuum table is attached? | Please push 'No'
when discontinue 'Yes' when continuing.”
虽然真空器已被安装,是否也移动基板幅宽?|执行,请按[]﹔停止,请按[]
E292000 No registered data
没有注册数据。
[Cause]
The following procedures were taken place when the number of the registered issue of Mark Database
is zero.
1. Press [Rename(C)] button or [Delete(D)] button on the Mark Database Management screen.
2. Press [Replace(A)] button on the Registration Mark Database screen.
3. Press [Copy(C)] button on the Vision Copy screen.
[Treatment]
The procedures above can not be performed when there is no registry in the Mark Database.
E292001 Please select the mark
请选择标记。
[Cause]
1. Although [Rename (C)] button or [Delete(D)] button screen were pressed on the Mark Database
Management screen, there is no selected mark to be an object of the action.
2. Although [Copy(C)] button was pressed on the Vision Copy screen, there is no selected mark to
be an object of the action.
[Treatment]
Please select a mark to be an object of each action.