Nozzle returning was requested to a head which does not have any nozzles on it. A cause is either that
a nozzle is actually not on the head or that the laser sensor is broken.
[Treatment]
1. If there is no nozzle on the head.
The nozzle is likely to have been taken off manually.
2. If the head has a nozzle on it.
There is a possibility that the MCM board in the laser sensor is not installed properly or the sensor
itself is broken. Please turn off the power supply and see if the MCM board is installed in the sensor
correctly.
E610026 The gotten nozzle width does not meet that of allocated nozzle
测定的吸嘴宽度与设置的吸嘴宽度不一致。
[Cause]
The outer shape of a nozzle which was gotten from ATC does not meet the outer shape of a nozzle
which is assigned in the Machine Setup. The cause is either that the nozzle were changed manually or
that the window of the laser sensor is dirty.
[Treatment]
1. If nozzles were changed manually.
Please perform the ATC nozzle allocation. The ATC Nozzle allocation can be performed by selecting
[Machine Setup] from the menu bar, and then [Setting Group(G)] [ATC Nozzle Allocation(A)].
2. If nozzles were not changed manually.
‧Please clean the window of the laser sensor. You can check the dirt of the window with the
following procedures. Select [Manual Control] from the menu bar, and then select [Control(C)]
[Head(H)] [Laser Control(L)]. Select a concerned laser sensor in 'Control' unit, and then select 'Image
displaying' from 'Control Item' frame. By enabling ON, an image data will be shown.
‧If the treatment1 does not work, or if the image data does not appear, there is a possibility that the
MCM board in the laser sensor is not installed properly or the sensor itself is broken. Please turn off
the power supply and see if the MCM board is installed in the sensor correctly.
E610027 An error occurred when setting Laser window size
设置激光窗口大小发生出错。
[Cause]
An error occurred when setting a window size to check a nozzle presence by the laser recognition
unit.
[Treatment]
There is a possibility that the laser recognition unit has a problem. You can check if it is fine or now
with the following procedures. Please select [Manual Control] from the menu bar, and then select
[Control(C)] [Head(H)] [Laser Control(L)].Select a concerned laser sensor in 'Control' unit, and then
select 'Image displaying' from 'Control Item' frame. By enabling ON, an image data will be shown. At
this point, if the image data does not get shown, please turn off the power supply and try again. If the
image data does not get shown even after the retry, MCM board in the laser sensor is not installed
properly or the sensor itself is broken. Please turn off the power supply and see if the MCM board is
installed in the sensor correctly.
E610028 An error occurred when detecting the presence of Laser nozzle
检查吸嘴是否存在时发生错误。
[Cause]
An error occurred when setting a window size to check a nozzle presence by the laser recognition
unit.
[Treatment]
There is a possibility that the laser recognition unit has a problem. You can check if it is fine or now
with the following procedures. Please select [Manual Control] from the menu bar, and then select
[Control(C)] [Head(H)] [Laser Control(L)].Select a concerned laser sensor in 'Control' unit, and then
select 'Image displaying' from 'Control Item' frame. By enabling ON, an image data will be shown. At
this point, if the image data does not get shown, please turn off the power supply and try again. If the
image data does not get shown even after the retry, MCM board in the laser sensor is not installed
properly or the sensor itself is broken. Please turn off the power supply and see if the MCM board is
installed in the sensor correctly.
E610029 An error occurred when learning laser height of Laser nozzle
激光识别器测量激光高度发生错误
[Cause]
An error occurred when measuring a nozzle length by the laser recognition unit.
[Treatment]
There is a possibility that the laser recognition unit has a problem. You can check if it is fine or now
with the following procedures. Please select [Manual Control] from the menu bar, and then select
[Control(C)] [Head(H)] [Laser Control(L)].Select a concerned laser sensor in 'Control' unit, and then
select 'Image displaying' from 'Control Item' frame. By enabling ON, an image data will be shown. At
this point, if the image data does not get shown, please turn off the power supply and try again. If the
image data does not get shown even after the retry, MCM board in the laser sensor is not installed
properly or the sensor itself is broken. Please turn off the power supply and see if the MCM board is
installed in the sensor correctly.
E610030 Nozzles can not be detected
没有发现吸嘴。
[Cause]
No nozzle could not be found in the Nozzle presence check by laser. Nozzles are not set in the ATC.
[Treatment]
Please set nozzle(s) on ATC and perform the ATC nozzle allocation. The ATC Nozzle allocation can
be performed by selecting [Machine Setup] from the menu bar, and then [Setting Group(G)] [ATC
Nozzle Allocation(A)].
E610031 Parameter for the cylinder is not correct
圆筒的参数不正确。
[Cause]
The specifying of ATC position is abnormal. The data in the machine is broken or the version of the
software that is installed on the machine is not correct.
[Treatment]
‧Please turn off the power supply of your machine and reboot it.
‧If the error occurred after the installation or the version up of the software, you need to re-install
the software.
‧If the treatments above do not work, there is a possibility that board(s) in the machine is broken.
You need to replace it(them) with new ones.
E610032 The head is not set to use
Head 处于不使用状态。
[Cause]
The specified head is not enabled to use. The head is set to not use in the Machine Setup.
[Treatment]
Please set the concerned head to use in the Machine Setup or try another head. You can set the head
to use in the Machine Setup with the following procedures. Select [Machine Setup] from the menu
bar, and then select [Setting Group(G)][Use Unit(D)]. Open a dialog with a tub 'Use Unit1', and check
in the checkbox of a concerned head.
E610033 ATC X coordinate is abnormal
X 坐标参数不正确。
[Cause]
The specified ATC X coordinate is abnormal. Or the specified coordinate exceeds the permissive
range of the nozzle exchange. The data in the machine is broken or the version of the software that is
installed on the machine is not correct.
[Treatment]
‧Please turn off the power supply of your machine and reboot it.
‧If the error occurred after the installation or the version up of the software, you need to re-install
the software.
‧If the treatments above do not work, there is a possibility that board(s) in the machine is broken.
You need to replace it(them) with new ones.
E610034 ATC Y coordinate is abnormal
Y 坐标参数不正确。