JUKI贴片机错误代码.pdf - 第66页
The laser detection height of no zzle, that was automatically l e arned, was too high. A nozzle which is shorter by over 1mm than a standard nozzle was detected. The no zzle length might be too short . [Treatment] Please…
There is no head available.
[Treatment]
Please set any necessary heads to “use” in the Use unit in Machine Setup.
E301024 “Selected device is disable. | Please reselect other device on HOD”
“被选设备是不能使用设备。|请重新选择别的设备。”
[Cause]
Since the device selected by HOD is non-use device (it is set to “not use” in the Use unit in Machine
Setup), you can not go into the teaching mode.
[Treatment]
Please select a device available.
E301025 “MTC is disable”
“MTC 不能使用。”
[Cause]
MTC can not be controlled since it is non-use device (it is set to “not use” in the Use unit in Machine
Setup)
[Treatment]
Please set the MTC to “use” in the Use unit in Machine Setup.
E301026 “Servo is in the free state”
“伺服处于未使用状态。”
[Cause]
The axis could not move since the servo is not locked.
[Treatment]
Please lock the servo with S-FREE switch.
W301027 “Teached data is invaled”
“示教数据无效。”
[Cause]
When an error caused by 'out of the measurement range' occurred while learning the Z axis coordinate
by HMS (when “---” is shown for Z in the teaching dialog), you can not learn the coordinate even if
you hit the enter key on HOD. The coordinate also can not be learned when other error occur while
teaching.
[Treatment]
When you learn the coordinate of Z axis by HMS, please make sure that the coordinate is within the
measurement range.
E301028 “Length of the nozzle is too short. | Please check the nozzle”
“吸嘴长度过短。|请检查吸嘴。”
[Cause]
The laser detection height of nozzle, that was automatically learned, was too high. A nozzle which is
shorter by over 1mm than a standard nozzle was detected. The nozzle length might be too short.
[Treatment]
Please check the nozzle length. [Cause]
E301029 “Vacuum is not ON.”
“没有起动真空器。”
E301032 “MTC is in the supply state”
“MTC 补充状态。”
[Cause]
MTC can not be controlled since it is in the Supply (component change) state.
[Treatment]
Please make MTC a normal status.
E301033 “Password is different from a predetermined one.”
“密码不一致。”
W301034 “The Height of nozzle exceeds a regulated value.%7.4lf mm”
“吸嘴高度超过规定值。%7.4lf mm”
E301035 “MTS is disable”
“不能使用 MTS。”
[Cause]
MTS can not be controlled since it is non-use device (it is set to “not use” in the Use unit in Machine
Setup)
[Treatment]
Please set the MTS to “use” in the Use unit in Machine Setup.
E301036 “MTS power off”
“没有打开 MTS 电源。”
[Cause]
Failed to draw the MTS tray out since the MTS was not ON.
[Treatment]
Please turn on the power supply of MTS.
E301037 “MTS offline”
“MTS 处于脱机状态。”
[Cause]
Failed to draw the MTS tray out since the MTS was not online.
[Treatment]
Please make MTS online.
E301038 “MTS cannot move because of cover opening”
“主机盖被打开时,MTS 不能工作。”
[Cause]
Failed to draw the MTS tray out since the cover of the machine was open.
[Treatment]
Please close the cover.
E301039 “The door of MTS opens”
“MTS 机箱门被打开。”
[Cause]
Failed to draw the MTS tray out since the MTS door was open.
[Treatment]
Please close the MTS door.
E301040 “There is no specified stacker with the tray steps number”
“指定阶层托盘存储箱不存在。”
[Cause]
Failed to draw the MTS tray out since there was no stacker which has the specified number of trays.
[Treatment]
Please set the stacker with specified number of trays.
E301041 “Because the IC collection belt is assembled to a rear side, |MTS cannot select.”
“因 IC 回收器安装在后侧,|不能选择 MTS。”
E301042 “Because MTS is selected, the IC conveyor belt is not assembled to a rear side”
“因 MTS 已被选定。|不能把 IC 回收器安装在后侧。”
[Cause]
When MTS was set to use, IC conveyor belt is not available on the rear side.
[Treatment]
You need to disable MTS or install the IC Collection belt on the front side to use.
E301043 “Starting Parameter Error.”
“起动参数错误。”
E301044 “Nozzle length is too long. Please check out the nozzle”
“吸嘴过长。|请检查吸嘴。”
[Cause]
The laser detection height of nozzle, that was automatically learned, was too low. A nozzle which is
longer by over 1mm than a standard nozzle was detected. The nozzle length might be too long.
[Treatment]
Please check the nozzle length.