JUKI贴片机错误代码.pdf - 第258页

E620009 X driver alarmed. <%s> “ “ X 轴驱动警报 ” [Cause] An abnormal matter happene d to the X axis driver. X 轴驱动器发生错误。 [Treatment] Please perform proper treatment s t hat are corresponding to the error numbers shown b…

100%1 / 464
E620003 Area sensor perceived.”
发现超出范围。
[原因]
因某种理由范围传感器起作用而引起错误。
[解决]
请解除范围传感器起作用的原因。
E620004 Feeder sensor detected.”
发现传送带浮动。
[原因]
因某种理由传送带浮动传感器起作用而引起错误。
[解决]
请解除传送带浮动传感器起作用的原因。
E620005 X limit sensor perceived.”
X 轴移动超出界限。
[原因]
如果 X 轴的界限传感器上面有轴时,就显示此信息。
[解决]
从界限传感器上,用手动移动轴之后,请按[确定]键。
E620006 Xr limit sensor perceived.”
X 轴移动超出界限。
[原因]
如果右 X 轴的界限传感器上面有轴时,就显示此信息
[解决]
从界限传感器上,用手动移动轴之后,请按[确定]键。
E620007 Y limit sensor perceived.”
Y 轴移动超出界限。
[原因]
如果 Y 轴的界限传感器上面有轴时,就显示此信息。
[解决]
从界限传感器上,用手动移动轴之后,请按[确定]键。
E620008 Yc limit sensor perceived.”
Yc 移动超出界限。
[原因]
如果 Yc 轴的界限传感器上面有轴时,就显示此信息。
[解决]
从界限传感器上用手动移动轴之后,请按[确定]键。
E620009 X driver alarmed. <%s>
X 轴驱动警报
[Cause]
An abnormal matter happened to the X axis driver.
X 轴驱动器发生错误。
[Treatment]
Please perform proper treatments that are corresponding to the error numbers shown below. If the
treatments are not enough, please take a note of the error No. and the details (* side DATA1= **
DATA2= ** DATA3= **) and contact our technical service dept. for information.
根据以下显示的错误编号进行相应处理。
即使进行相应处理也发生错误时,请记好错误代码和详细代码(side DATA1= **
DATA2= ** DATA3=**),与代理点或本公司技朮服务部联系。
[相应处理]
DATA3 = 1 [over-electric current(过电流)]
If the error occurs when turning the servo on: There is a possibility of the miswiring of the motor
circuits. Please examine the wiring.
伺服一启动就发生错误:马达电路的配线故障。请检查配线。
If the error occurs while the servo is ON(the motor is vibrating): Please re-adjust the gain.
伺服运转中发生错误(马达处于震动状态):请再调整增益。
If the error occurs when accelerating/decelerating: Please examine the inertia.
加速、减速时发生错误:请检查惯性负荷。
If the error occurs when revolving: Please examine the torque.
旋转时发生错误:请检查扭转负荷。
DATA3 = 2 [over-load(超负荷]
If the error occurs when turning the servo on: There is a possibility of the miswiring of the motor
circuits. Please examine the wiring.
伺服一启动就发生错误:马达电路的配线故障。请检查配线。
If the error occurs while the servo is ON(the motor is vibrating): Please re-adjust the gain.
伺服运转中发生错误(马达处于震动状态):请再调整增益。
If the error occurs when accelerating/decelerating: Please examine the inertia.
加速、减速时发生错误:请检查惯性负荷。
If the error occurs when revolving: Please examine the torque.
旋转时发生错误:请检查扭转负荷。
DATA3 = 3 [Driving power supply abnormality(驱动电源异常)
]
Please examine the value of electric currency that is sent to the driver from the power supply unit. If
nothing is wrong with it, please examine CP1 of the power supply unit. If anything is not wrong with
it, please change drivers or motors.
请检查输入电源。如果电源没有故障,请检查电源装置的 CP1。如 CP1 也没有故障,
更换驱动器或马达。
DATA3 = 4 [EEPROM abnormalityEEPROM 异常)]
Please change drivers(CPU boards).
请更换驱动器(CPU )
DATA3 = 5 [heating(发热)]
Please change drivers. If the error occurs again after the axis moves for a while, please examine the
FAN motor that is under the driver. If nothing is wrong with it, please examine the torque.
请更换驱动器。如果运转一段时间后出现发热现象,请检查驱动器底部的风扇。如果都没
有问题,请检查扭转负荷。
DATA3 = 6 [Encoder abnormality(编码器异常)]
Please examine the wiring of the encoder cables. If anything is wrong with it, then please change
motors.
请检查编码器电缆。如果电缆没有问题,请更换马达。
DATA3 = 7 [CPU abnormalityCPU 异常)]
Please change drivers(CPU boards).
请更换驱动器(CPU )
E620010 Y driver alarmed. <%s>
Y 轴驱动警报
[Cause]
An abnormal matter happened to the Y axis driver.
Y 轴驱动器发生错误。
[Treatment]
Please perform proper treatments that are corresponding to the error numbers shown below. If the
treatments are not enough, please take a note of the error No. and the details (* side DATA1= **
DATA2= ** DATA3= **) and contact our technical service dept. for information.
根据以下显示的错误编号进行相应处理。
即使进行相应处理也发生错误时,请记好错误代码和详细代码(side DATA1= **
DATA2= ** DATA3=**),与代理点或本公司技朮服务部联系。
[相应处理]
DATA3 = 1 [over electric current (过电流)]