JUKI贴片机错误代码.pdf - 第361页
‧A PWB with mass of 2kg or more. 2 If the PWB was NOT on the position where it is detected by t he STOP sensor on the center station on the Exit si de when the error occurred. If the STOP sensor does not get O FF when a …
on the center station on the Entrance side.
The PWB can not move for it got caught on the conveyor for some reason.
1) The conveyor width is not matching the PWB width. Please re-adjust the conveyor width.
2) The PWB you are trying to convey does not match the specifications of your machine. The
following cases do not match your machine.
‧A PWB with thickness of 0.3mm or less. Or a PWB with thickness of 4mm or more.
‧A PWB with mass of 2kg or more.
2 If the PWB overran the STOP sensor when the error occurred.
The STOP sensor on the center station on the Entrance side is not detecting the PWB. Please select
[Manual Control] from the menu bar, and then select [Control(C)] [Conveyor(C)] [Independent
Control of Conveyor(I)] to see the status of STOP sensor on the center station on the Entrance side in
the 'Status' frame.
1) The sensitivity of the STOP sensor on the center station on the Entrance side may be too high.
Please re-adjust the sensitivity of the sensor, using the volume control knob attached to the sensor.
2) If the treatment1 does not work, there is a possibility that the STOP sensor on the center station on
the Entrance side is broken. It could be that the wiring came out of the connector part, that a contact
pin in the connector part is broken, that wiring got cut off, or that sensor itself is broken. Please
examine the wiring and the connector. If any of them are broken, you need to replace them with the
new ones.
3) If the treatment2 does not work, PCB is broken or the wiring between the PCBs is bad.
E650345 “Idle PWB Conveying Error :| PWB conveying error of the center buffer. | Please remove it.”
“传送基板(通过)错误 :|强行停止入口侧中心缓冲区错误。”
E650352 “Idle PWB Conveying error : PWB conveying error of the center station on the Exit side. The
process is forcibly terminated. Please remove on the conveying route”
“传送基板(通过)错误 :|STOP2 传感器OFF超时。”
[Cause]
This error occurs if the STOP sensor on the center station on the Exit side got OFF then ON again,
but it does not get OFF even if a certain amount of time has passed since it got ON again when
conveying a PWB on the center station on the Exit side out to the OUTPUT buffer.
[Treatment]
1 If the PWB was on the position where it is detected by the STOP sensor on the center station
on the Exit side when the error occurred.
The PWB can not move for it got caught on the conveyor for some reason.
1) The conveyor width is not matching the PWB width. Please re-adjust the conveyor width.
2) The PWB you are trying to convey does not match the specifications of your machine. The
following cases do not match your machine.
‧A PWB with thickness of 0.3mm or less. Or a PWB with thickness of 4mm or more.
‧A PWB with mass of 2kg or more.
2 If the PWB was NOT on the position where it is detected by the STOP sensor on the center
station on the Exit side when the error occurred.
If the STOP sensor does not get OFF when a PWB is properly being conveyed, there is a possibility
that the sensor is detecting something else. Please select [Manual Control] from the menu bar, and
then select [Control(C)] [Conveyor(C)] [Independent Control of Conveyor(I)] to see the status of
STOP sensor on the center station on the Exit side in the 'Status' frame.
1) The sensitivity of the STOP sensor may be too high. Please re-adjust the sensitivity of the sensor,
using the volume control knob attached to the sensor.
2) If the treatment1 does not work, there is a possibility that the STOP sensor is broken. It could be
that the wiring came out of the connector part, that a contact pin in the connector part is broken, that
wiring got cut off, or that sensor itself is broken. Please examine the wiring and the connector. If any
of them are broken, you need to replace them with the new ones.
3) If the treatment2 does not work, PCB is broken or the wiring between the PCBs is bad.
E650353 “Idle PWB Conveying Error : PWB conveying error of the center station on the Exit side. The
process is forcibly terminated. Please remove on the conveying route”
“传送基板(通过)错误 :|C.OUT2传感器OFF超时。”
[Cause]
This error occurs if the C-OUT sensor on the center station on the Exit side got OFF then ON again,
but it does not get OFF even if a certain amount of time has passed since it got ON again when
conveying a PWB on the center station on the Exit side out to the OUTPUT buffer.
[Treatment]
1 If the PWB was on the position where it is detected by the C-OUT sensor on the center station
on the Exit side when the error occurred.
The PWB can not move for it got caught on the conveyor for some reason.
1) The conveyor width is not matching the PWB width. Please re-adjust the conveyor width.
2) The PWB you are trying to convey does not match the specifications of your machine. The
following cases do not match your machine.
‧A PWB with thickness of 0.3mm or less. Or a PWB with thickness of 4mm or more.
‧A PWB with mass of 2kg or more.
2 If the PWB was NOT on the position where it is detected by the C-OUT sensor on the center
station on the Exit side when the error occurred.
If the C-OUT sensor does not get OFF when a PWB is properly being conveyed, there is a possibility
that the sensor is detecting something else. Please select [Manual Control] from the menu bar, and
then select [Control(C)] [Conveyor(C)] [Independent Control of Conveyor(I)] to see the status of
C-OUT sensor on the center station on the Exit side in the 'Status' frame.
1) The sensitivity of the C-OUT sensor may be too high. Please re-adjust the sensitivity of the sensor,
using the volume control knob attached to the sensor.
2) If the treatment1 does not work, there is a possibility that the C-OUT sensor is broken. It could be
that the wiring came out of the connector part, that a contact pin in the connector part is broken, that
wiring got cut off, or that sensor itself is broken. Please examine the wiring and the connector. If any
of them are broken, you need to replace them with the new ones.
3) If the treatment2 does not work, PCB is broken or the wiring between the PCBs is bad.
E650354 “Idle PWB Conveying Error : PWB conveying time out error of the center station on the Exit side.
The process is forcibly terminated. Please remove on the conveying route”
“传送基板(通过)错误 :|基板进入出口侧中心缓冲区超时。”
[Cause]
This error occurred because the STOP sensor on the center station on the Exit side did not get ON
even though a certain amount of time has passed since the C-OUT sensor on the center station on the
Entrance side got OFF when conveying a PWB on the center station on the Entrance side to the center
station on the Exit side. Usually, this error occurs when a PWB can not go through the conveyor for
some reason.
[Treatment]
1 If the PWB was on the position where it is NOT detected by the C-OUT sensor on the center
station on the Entrance side or the STOP sensor on the center station on the Exit side when the error
occurred.
The PWB can not move for it got caught on the conveyor for some reason.
1) The conveyor width is not matching the PWB width. Please re-adjust the conveyor width.
2) The PWB you are trying to convey does not match the specifications of your machine. The
following cases do not match your machine.
‧A PWB with thickness of 0.3mm or less. Or a PWB with thickness of 4mm or more.
‧A PWB with mass of 2kg or more.
2 If the error occurred because the conveying belt on the center station on the Entrance side
stopped and the PWB did not get conveyed out when conveying the PWB on the center station on the
Entrance side.
The error occurs if the C-OUT sensor on the Entrance side gets temporarily OFF before the PWB has
gone through the station.
1) The error occurs if the C-OUT sensor on the Entrance side gets temporarily OFF when the PWB
has gone through the station because the PWB has holes on it or the edge of the PWB is chipped.
Please select [Setup(S)] [Setup(S)] from the menu bar, and then select [Setting Group(G)] [PWB
conveyor(C)]. Set 'Delay for conveyor sensor' to disable the holes or chips on PWBs.
2) The error occurs if C-OUT sensor temporarily gets OFF because the PWB has a part that fully
reflects. This error is likely to occur when you use boards such as metal jig board. As a treatment,
please set 'Delay for conveyor sensor', following the steps mentioned in the treatment1.
3 If the PWB overran the STOP sensor on the center station on the Exit side when the error
occurred.