" 永久的常驻的吸嘴分配失败。 " E6456 “ Permanently resident feeder allocation fail ed. “ " 永久的常驻的进料器分配失败。 " E6457 “ Already assigned pick data allocation failed. “ " 已经指定的挑选数据分配失败。 " E6458 “ A station to…

100%1 / 464
"%dth 程序中的图像数据不完全。"
E6427 Specified number supplied in %dth program exceeds resource.
" %dth程序供给指定数量超过资源数。"
E6428 Assigned placement data in %dth program exist in multiple stations.
"%dth 程序中的指定贴片数据存在于多个位置。"
E6429 Assigned pick data in %dth program exist in multiple stations.
"%dth 程序中的指定挑选数据存在于多个位置。"
E6440 The number of placemently resident nozzles exceeds the resource.
"固定吸嘴数量超过资源量。"
[Cause]
The number of the placement nozzles has exceeded the available number of resources.
[Deal]
Increase the number of nozzles specified in the MSL setup resource.
E6441 Number of permanent feeders exceeds resource.
"固定进料器数量超过资源量。"
E6442 %s over resource.
[Cause]
The number of feeders has exceeded the available number of resources.
[Deal]
Increase the number of feeders specified in the MSL setup resource.
E6450 Permanent data cannot be set.
"永久数据不能被设置。"
E6451 Protected data cannot be set.
"保护数据不能被设置。"
E6452
Production control data allocation failed.
"产品控制数据分配失败。"
E6453 Production condition data allocation failed.
"产品情况数据分配失败。"
E6454 Global fiducial data allocation failed.
"球型基准数据分配失败。"
E6455 Permanently resident nozzle allocation failed.
"永久的常驻的吸嘴分配失败。"
E6456 Permanently resident feeder allocation failed.
"永久的常驻的进料器分配失败。"
E6457 Already assigned pick data allocation failed.
"已经指定的挑选数据分配失败。"
E6458 A station to which pick data have already been assigned is excluded as an object of partition.
"已经被指定的选择数据位置作为区分目标被排除."
E6459 Already assigned placement data allocation failed.
"已经指定的贴片数据分配失败。"
E6460 The head corresponding to the already assigned placement data cannot be used.
"已分配给位置的相应的头没有使用"
[Cause]
Indicates that the station specified for the feeder in mounting and absorption data is different from the
allocated station.
[Deal]
Use the automatic selection to specify the station for the mounting data and absorption data for
optimization.
E6461 The already assigned placement data MTC cannot be used.
"不能使用已指定贴片数据 MTC"
E6462 Some pick data are designated in non-distrubutable station.
"不能设置已指定贴片数据吸嘴。"
[Cause]
Indicates that the data for the absorbing point specification has been already used for the occupation
data.
[Deal]
Use the automatic selection to specify the station for the mounting data and absorption data for
optimization.
E6463 Some placement data are designated in non-distributable station.
"已指定的贴片数据贴片层相互矛盾"
[Cause]
Indicates that the data for mounting specification is allocated for more than one station.
[Deal]
Use the automatic selection to specify the station for the mounting data and absorption data for
optimization.
E6464 Already assigned placement data chip standing cannot be detected.
"不能检测到已指定贴片数据的固定芯片站立。"
[Cause]
Indicates that the number of the mounting positions has exceeded the maximum value, i.e., checking
the occupation data was failed.
[Deal]
Decrease the number of mounting positions.
E6465 Already assigned placement data chip standing cannot be detected.
[Cause]
Indicates that inconsistency was found in the layer specification.
[Deal]
Reset the layer allocation for optimization.
E6500 Data cannot be assigned to machine station.
"数据不能被指定到机器位置。"
E6550 Failed to distribute data.
"没有%d 数据能被指定到机器位置。"
[Cause]
An invalid data was found during data allocation for the mounting or absorption list. (See the sub-list
for details.)
(Detailed messages corresponding to each station.)-Unavailable for specification since it is an
applicator. Type 770 or 775 station.
-Unavailable for dividing destinations. Station with the balance option check is disabled or 0 balance.
-MTC is disabled. Station unavailable for using MTC.
-MTS is disabled. Station unavailable for using MTS.
-Chip standup-detection is disabled. Station unavailable for chip-standup inspection.
-Coplanarity inspection is disabled. Station unavailable for coplanarity inspection.
-The verification is disabled. Station unavailable for the verification.-IC mark part is disabled. Station
unavailable for IC mark.
-Tray-holder is disabled. Type 770 or 775station.
-Nozzle 5 is disabled. Type 770 or 775 station.
-44 and 56 mm feeders are disabled. Type 770 or 775 station.
-The value specified for the outside dimension deviates from the range and not acceptable. Outside
dimension applied to the centering is out of the range.
-The value specified for the part height deviates from the range and not acceptable. Height applied to
the centering is out of the range.-Every head is disabled. Station with all heads disabled.
-General-purpose head is disabled. Station unavailable for general-purpose head.