JUKI贴片机错误代码.pdf - 第404页

“ 把 %s 放回模具站点。 ” [Cause] The jig of is on the Cali bration block or is being picked up. [Treatment] “ OK ” button will ret urn the jig to the ji g station. E999999 “ Message File Error .” “ 错误代码文件发生错误。 ” 第九章 程序编辑系统 [ 程序编…

100%1 / 464
inquiry.
Q907011 Return to home has not yet been completed. Return to home?
尚未完成返回原点。|是否进行返回原点?
[Cause]
The axis has not yet been returned to home. You are asked if you want to perform the Home returning
of the axis?
[Treatment]
YES button will return the axis to home, and continue the process. NO button will not return the
axis to home, and continue the process.
Q907021 Cannot return component. Trash component?
不能归还组件。|是否废弃?
[Cause]
A component was detected in the Component presence checking that is performed when returning
nozzle to ATC. The component can not be returned since its pick position is unknown. You are asked
if the component can be disposed.
[Treatment]
YES button will dispose the component at a disposal position. NO button will move the head to
the waiting position for nozzle removal, and request for a component removal.
I908001 Remove the component from %s
请取下%s上的组件。
[Cause]
The nozzle can not be returned to ATC since something, such as a component, is attached to the
nozzle.
[Treatment]
Please remove the component from the head manually.
I908002 %s vacuum is turned on.|If a component is currently being picked, remove it.
%s的真空设置为ON|若组件贴在上面,请除掉。
I909001 Nozzle is removed from %s to ATC
卸下%s 的吸嘴。
[Cause]
A nozzle has still been on the head.
[Treatment]
OK button will check the component presence, and return the nozzle making sure that no
components on it.
I909002 Calibration jig for laser alignment will be returned to jig station
%s 放回模具站点。
[Cause]
The jig of is on the Calibration block or is being picked up.
[Treatment]
OK button will return the jig to the jig station.
E999999 Message File Error.”
错误代码文件发生错误。
第九章 程序编辑系统
[程序编辑系统、EPU]
E1001Obtaining message information failed.
"获得消息失败。"
E1002Message file read-in failed.
"读入信息文件失败。."
E1003Start-up of communication processing failed.
"激活信息通讯处理失败。."
E1004 Initialization of communication processing failed.
"初始化信息通讯处理失败。"
E1005 Communication processing has not been started up.
"信息通讯处理还未被激活。."
E1006 Read-in of communication processing initialization file failed.
"读入信息处理初始化文件失败."
E1007 Allocation of area for use in transmission failed.
"为传送分配区域失败。"
E1008 There is no file to be transmitted.
"没有文件被传输。"
E1009 There is no optimized file to be transmitted. <%s>
"没有优化文件被传送。 <%s>"
E1010 Transmission failed <Station ID = %d Transmission status = %s>
"传送失败。 <<位置 ID = %d <Transmission status = %s>"
E1011 A reception error occurred. <Station ID = %d Reception status = %s>
"发生一个接收错误。 <位置 ID = %d <Reception status = %s>"
E1012 Memory was insufficient at time of reception. <Station ID = %d Reception status = %s>
"接收时内存不足。 <位置 ID = %d.3 <Reception status = %s>"
E1013 INI file read-in failed.
"读入 INI 文件失败。"
[Cause]
Appears if the required no line is set during the MSL setup.
[Deal]
Make sure again that the required line is set during the MSL setup.
E1014 Profile read-in failed.
"读入剖面失败。"
E1015 Timer used for communication has not been set.
"为信息通讯使用的定时器没有设置."
E1016 File creation at time of data reception failed.
"接受数据时创建文件失败。"
E1017 Station is not in condition to transmit. <Station ID = %d>
"所在位置没有条件被传送。 <位置 ID = %d>"
E1018 A status error has occurred.
"发现一个位置错误。."
E1019 Input is incorrect.
"输入错误。"
[Cause]
Invalid values or symbols for the range is specified.
[Deal]
Enter valid value or symbols for the item.
E1020
Memory cannot be secured.
"不能保护内存。"
[Cause]
Allocating memory was failed.
[Deal]
Retry the task after exiting from unnecessary applications.
E1021 Start-up cannot be done at same time as MSL setup.