JUKI贴片机错误代码.pdf - 第287页
E631023 “ ViRecog Error: Some leads are missing. Please examine Vision da ta ” “ 组件识别错误 : 引脚数少于设置数 ” [Cause] Some leads are missing. The specified lead missing is wrong. The component's lead pitch is different. Pick…
E631021 “ViRecog Error: The position of the lead tip is illegal. Please examine the component”
“组件识别错误:引脚长度错误”
[Cause]
The leads are irregular in length.
The lead is too dark.
The light is either too bright or too dark.
The light is dirty.
The camera lens is dirty.
The light cable almost gets cut off.
The brilliancy of LED is varying.
[Treatment]
Please examine the light parameter in the production program.
Please adjust the light parameter in the production program.
Please clean the light.
Please clean the camera lens.
Please change the light cables.
Please re-adjust the electric currency of the light.
Please change the lights and re-adjust the electric currency of the new light.
Please change the light boards and re-adjust the electric currency of the new board.
E631022 “ViRecog Error: Lead pitch is wrong. Please examine Vision data”
“组件识别错误:引脚间距错误”
[Cause]
The component's lead pitch is different.
The light is either too bright or too dark.
The light is dirty.
The camera lens is dirty.
The light cable almost gets cut off.
The brilliancy of LED is varying.
[Treatment]
Please examine the lead pitch in the production program.
Please examine the light parameter in the production program.
Please adjust the light parameter in the production program.
Please clean the light.
Please clean the camera lens.
Please change the light cables.
Please re-adjust the electric currency of the light.
Please change the lights and re-adjust the electric currency of the new light.
Please change the light boards and re-adjust the electric currency of the new board.
E631023 “ViRecog Error: Some leads are missing. Please examine Vision data”
“组件识别错误:引脚数少于设置数”
[Cause]
Some leads are missing.
The specified lead missing is wrong.
The component's lead pitch is different.
Picking posture is not correct.
The light is either too bright or too dark.
The light is dirty.
The camera lens is dirty.
The light cable almost gets cut off.
The brilliancy of LED is varying.
[Treatment]
Please examine the number of leads in the production program.
Please examine the lead missing in the production program.
Please examine the lead pitch in the production program.
Please examine the Pick data in the production program.
Please examine the light parameter in the production program.
Please adjust the light parameter in the production program.
Please clean the light.
Please clean the camera lens.
Please change the light cables.
Please re-adjust the electric currency of the light.
Please change the lights and re-adjust the electric currency of the new light.
Please change the light boards and re-adjust the electric currency of the new board.
E631024 “ViRecog Error: The number of leads is too large. Please examine Vision data”
“组件识别错误:引脚数多于设置数”
[Cause]
There are too many leads.
The specified lead missing is wrong.
The component's lead pitch is different.
Picking posture is not correct.
The light is either too bright or too dark.
The light is dirty.
The camera lens is dirty.
The light cable almost gets cut off.
The brilliancy of LED is varying.
[Treatment]
Please examine the number of leads in the production program.
Please examine the lead missing in the production program.
Please examine the lead pitch in the production program.
Please examine the Pick data in the production program.
Please examine the light parameter in the production program.
Please adjust the light parameter in the production program.
Please clean the light.
Please clean the camera lens.
Please change the light cables.
Please re-adjust the electric currency of the light.
Please change the lights and re-adjust the electric currency of the new light.
Please change the light boards and re-adjust the electric currency of the new board.
E631025 “ViRecog Error: Failed to detect leads. Please examine the picking posture”
“组件识别错误:没有发现引脚”
[Cause]
The picking posture is not correct.
The component is not being picked.
The picked component is different from a component in the Component data.
The light is either too bright or too dark.
The light is dirty.
The camera lens is dirty.
The light cable almost gets cut off.
The brilliancy of LED is varying.
[Treatment]
Please examine the Pick data in the Production program.
Please examine the Component data (Vacuum value without component) in the Production program.
Please examine the Component data in the Production program.
Please examine the Vision data in the Production program.
Please examine the light parameter in the Production program.
Please adjust the light parameter in the Production program.
Please clean the light.
Please clean the camera lens.
Please change the light cables.
Please re-adjust the electric currency of the light.
Please change the lights and re-adjust the electric currency of the new light.
Please change the light boards and re-adjust the electric currency of the new board.
E631026 “ViRecog Error: The number of leads is too small. Please examine Vision data”