JUKI贴片机错误代码.pdf - 第225页

Please turn off the power supply of your machine. If the error occurs even after the reboot, please see if the cables are connected prope rly. If the error still occurs even when the cables are connected properly, you ne…

100%1 / 464
E610225 Fan stop error occurred
发生风扇被停止错误。
[Cause]
The cooking fan stopped.
[Treatment]
Please turn off the power supply of your machine. If the error occurs even after the reboot, please see
if the cables are connected properly. If the error still occurs even when the cables are connected
properly, you need to replace the cooling fan with a new one.
E610226The air pressure decrease error occurred
发生气压下降错误。
[Cause]
The air pressure is decreasing.
[Treatment]
The following causes can be possible. Please deal with the error based on the cause you have.
‧The air supplied to the unit is decreasing. The air pressure that should be supplied is 0.5  
0.05Mpa, so please see if the proper amount of air pressure is supplied or not.
‧The enough amount of the air necessary for the unit is not being supplied. This error is likely to
occur when a pipe to the unit is too thin or the capacity of the air compressor is too small. These two
can be the cause of the error especially when large components are picked simultaneously. You
need to deal with the air by replacing the pipe to the unit with a larger one.
‧The air regulator is wrung toward its minimum limit too much. Please loosen the air regulator to
make it 0.5   0.05Mpa.
‧The set value for the air pressure detecting sensor is too low. Please reset the value of the sensor
that is installed next to the air combination to 0.45Mpa.
‧The air pressure detecting sensor is broken. Please examine if a connecting cable connects to the
connector properly. If the cable connects to the connector properly, the sensor itself is broken.
E610227 The error not forecast occurred
发生未知错误。
[Cause]
An undefined error occurred.
[Treatment]
Please turn off the power supply of your machine and reboot it.
E610228 LZ1 Driver alarm occurred
发生 LZ1 驱动警报。
[Cause]
An abnormal matter happened to the Z axis servo driver on the right head1.
[Treatment]
Please turn off the power supply of your machine. If the error occurs even after the reboot, please see
if the cables are connected properly. If the error still occurs even when the cables are connected
properly, you need to replace the Z axis servo driver on the left head1 with a new one.
E610229 LZ2 Driver alarm occurred
发生 LZ2 驱动警报。
[Cause]
An abnormal matter happened to the Z axis servo driver on the right head2.
[Treatment]
Please turn off the power supply of your machine. If the error occurs even after the reboot, please see
if the cables are connected properly. If the error still occurs even when the cables are connected
properly, you need to replace the Z axis servo driver on the left head2 with a new one.
E610230 LZ3 Driver alarm occurred
发生 LZ3 驱动警报。
[Cause]
An abnormal matter happened to the Z axis servo driver on the right head3.
[Treatment]
Please turn off the power supply of your machine. If the error occurs even after the reboot, please see
if the cables are connected properly. If the error still occurs even when the cables are connected
properly, you need to replace the Z axis servo driver on the left head3 with a new one.
E610231 LZ4 Driver alarm occurred
发生 LZ4 驱动警报。
[Cause]
An abnormal matter happened to the Z axis servo driver on the right head4.
[Treatment]
Please turn off the power supply of your machine. If the error occurs even after the reboot, please see
if the cables are connected properly. If the error still occurs even when the cables are connected
properly, you need to replace the Z axis servo driver on the left head4 with a new one.
E610232 RZ1 Driver alarm occurred
发生 RZ1 驱动警报。
[Cause]
An abnormal matter happened to the Z axis servo driver on the right head1.
[Treatment]
Please turn off the power supply of your machine. If the error occurs even after the reboot, please see
if the cables are connected properly. If the error still occurs even when the cables are connected
properly, you need to replace the Z axis servo driver on the right head1 with a new one.
E610233 RZ2 Driver alarm occurred
发生 RZ2 驱动警报。
[Cause]
An abnormal matter happened to the Z axis servo driver on the right head2.
[Treatment]
Please turn off the power supply of your machine. If the error occurs even after the reboot, please see
if the cables are connected properly. If the error still occurs even when the cables are connected
properly, you need to replace the Z axis servo driver on the right head2 with a new one.
E610234 RZ3 Driver alarm occurred
发生 RZ3 驱动警报。
[Cause]
An abnormal matter happened to the Z axis servo driver on the right head3.
[Treatment]
Please turn off the power supply of your machine. If the error occurs even after the reboot, please see
if the cables are connected properly. If the error still occurs even when the cables are connected
properly, you need to replace the Z axis servo driver on the right head3 with a new one.
E610235 RZ4 Driver alarm occurred
发生 RZ4 驱动警报。
[Cause]
An abnormal matter happened to the Z axis servo driver on the right head4.
[Treatment]
Please turn off the power supply of your machine. If the error occurs even after the reboot, please see
if the cables are connected properly. If the error still occurs even when the cables are connected
properly, you need to replace the Z axis servo driver on the right head4 with a new one.
E610236 LT1 Driver alarm occurred
发生 LT1 驱动警报。
[Cause]
An abnormal matter happened to the Theta axis servo driver on the left head1.
[Treatment]
Please turn off the power supply of your machine. If the error occurs even after the reboot, please see
if the cables are connected properly. If the error still occurs even when the cables are connected
properly, you need to replace the Theta axis servo driver on the left head1 with a new one.
E610237 LT2 Driver alarm occurred
发生 LT2 驱动警报。
[Cause]
An abnormal matter happened to the Theta axis servo driver on the left head2.
[Treatment]